4. INTRODUCTION
The jGUN is worlds first and only Tension Gun calibrated for both bolt load as torqueing! This tensioning
gun guarantees safe, fast and simple operation without vibration.
The gun is powerful and yet light. All guns can operate without reaction arm or wrench. Unlike impact
wrenches, the jGUN never transmits working torque to the operator. The torque is applied between the
fastener and the reaction surface. The best result is achieved in combination with the HYTORC
LoadDISC or the HYTORC NUT. This manual provides information for the jGUN Single Speed, jGUN
Dual Speed Plus, jGUN NutRunner and WheelGUN.
Fig. 1: Application jGUN Single Speed
5. AIR SUPPLY MAINTENANCE SET (FRL UNIT)
The Filter Regulator Lubricator Unit (jGUN-FRL) must be used in combination with the too jGUN. The
jGUN air supply maintenance sets (FRL Unit) are exclusive for jGUN tools and vice versa. Damage may
occur to the air supply maintenance set or the product that is being operated due to misuse.
With the 3,5 meter hose this set is connected to the jGUN. The FRL Unit removes water and other
contaminations from the air supply, regulates the air pressure and mixes oil in the air for maintaining your
tool.
Operating the jGUN without the FRL Unit will void the warranty and may cause damage to the air motor
and gearbox. Incorrect setting of the lubricator unit may result in a shortage of lubrication to the air motor
and gearbox resulting in damage to the tool.
Fig. 2: Air supply maintenance set (FRL unit)
5.1 Requirements for the air supply
The air supply line must be ½ inch minimum diameter to allow adequate air flow to the jGUN.
The air supply must provide a minimum of 6,21 bar and 850 l/min (1,5 inch square drive needs
1450 L/Min) to reach maximum power.
Ensure that airline fittings are tight and leak free. Do not over tighten airline fittings.