background image

ASSEMBLY INSTRUCTIONS  (continued)

ASSEMBLY INSTRUCTIONS  (continued)

C

Page 4 of 7

   200810

 

Sensor Adjustment Lower For Short Coverage

Sensor Adjustment Higher For Long Coverage

Fig. 5

Fig. 4

Fig. 2

Fig. 3

Adjusting the Light Head: 

2. 

Keep the light heads (D) 30˚ below horizontal to avoid water d

amage and electrical shock.

Sensitivity of Motion Sensor 

       ● You can adjust the sensitivity of the motion sensor by using the “SENSITIVITY” selector located on the right 

           side of the bottom surface of the sensor. (See Fig. 4)

       ● Adjust motion sensor sensitivity to achieve desired performance.

       ● Approximate range for each setting from 10ft to 70ft.

Choose a mode by sliding the switch on the bottom of the sensor of the fixture. (See Fig.4 )

Note: When power is first applied, the light will turn on immediately. Wait for 30 seconds to allow the sensor 

to warm up.

1. TEST MODE (daytime and nighttime operation.)

     

●  Rotate knob on the bottom of the sensor to the “TEST” position. (See Fig.4 )

Adjusting the Sensor Head (C): 

1. Aim sensor head (C) toward desired detection area, maintaining a 

    5° - 40° downward angle to allow moisture to drain.

    Note: Make sure sensor head (C) is positioned with controls facing 

    toward the ground.

2. You can move the sensor head (C) up and down to change the

    coverage area. (See Fig. 1) 
    

Note: Range set too high may increase false triggering.

 

    (See Fig. 2 and Fig. 3 )

Fig. 1

1.Gently grasp the light heads (D) and tilt them left or right to adjust the light coverage area. Keep the light heads (D) at

   least 1” (25mm) away from the sensor.(See Fig. 5)

   

D

D2D

OFF

3MIN

5S

TEST

TIME

SENSITIVITY

LOW LEVEL

+

-

3H

6H

ASSEMBLY INSTRUCTIONS (continued)

ASSEMBLY INSTRUCTIONS  (continued)

ASSEMBLY INSTRUCTIONS  (continued)

FUNCTION AND OPERATION  (continued)

Summary of Contents for OW9227W

Page 1: ...y 9 00 a m 5 00 p m CST SKU Number 356 9227 356 9228 2 LIGHT OUTDOOR SENSOR LIGHT A B C D Model Number OW9227W OW9228BZ 200810 HARDWARE CONTENTS Note Hardware not shown actual size PACKAGE CONTENTS AA BB DD EE FF CC Mounting Screw X2 Wire Connector X3 Mounting Strap X1 Decorative cover X1 Fixture Mounting Screw X1 Gasket X1 ...

Page 2: ...pply wire rated for 140 F 60ºC Consult a qualified electrician before installation Do not connect this fixture to an electrical system that does not provide a means for equipment grounding Never use a fixture in a two wire system that is not grounded If you are not sure your lighting system has a grounding means do not attempt to install this fixture Contact a qualified licensed electrician for in...

Page 3: ...sh the shell B in and then twist clockwise to lock Repeat for the other shell B 6 Install bulbs not included See relamping label at socket area or packaging for maximum wattage allowed Before installing the light fixture under an eave the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock For eave mounted only Rotate the sensor...

Page 4: ... the light will turn on immediately Wait for 30 seconds to allow the sensor to warm up 1 TEST MODE daytime and nighttime operation Rotate knob on the bottom of the sensor to the TEST position See Fig 4 Adjusting the Sensor Head C 1 Aim sensor head C toward desired detection area maintaining a 5 40 downward angle to allow moisture to drain Note Make sure sensor head C is positioned with controls fa...

Page 5: ...oment on it will remain on for 3 hours During this 3 hours when motion is detected it turns to high level brightness and stays on as long as motion continues When the motion is no longer detected it remains high level brightness for the predetermined time you set 5s 3min and then turns to low level brightness automatically After the 3 hours it turns off when motion is detected again it turns to hi...

Page 6: ...etection distance of up to 70 feet at 77 degrees Fahrenheit See Fig 6 3 The sensor detects movement across a detection range of 240 degrees See Fig 7 4 The sensor will be more sensitive to motion across its detection path than motion directly towards it See Fig 8 5 To reduce possible nuisances do not mount the fixture near a heat source like an air conditioner vent or furnace exhaust or in a direc...

Page 7: ...s missing parts Before returning to your retailer call our customer service at 1 800 887 6326 Monday Friday 9 00 a m 5 00 p m CST TROUBLESHOOTING R R R CARE AND MAINTENANCE R Clean the glass and coated metal surfaces with a non abrasive cleaner Do not use any cleaners with chemicals solvents or harsh abrasives The motion detecting lens is coated with a specially painted finish and requires special...