PATON
MultiPRO
DC MMA/TIG/MIG/MAG
-22 -
7) [BSn] voltage reduction unit = OFF (by default)
a) ON
–
enabled
b) OFF
–
disabled
8) [Po.P] current pulsation mode = OFF (by default)
a) ON
–
enabled
b) OFF
–
disabled
9) [I.iP] pulse current = 90A (by default)
a) 8 ... 25
0А (change step 1А) for
MultiPRO-250
b) 10 ... 27
0А (change step 1А) for
MultiPRO-270
c) 12 ... 3
50А (change step 1А) for
MultiPRO-350
10) [I.PS] pause current = 90A (by default)
a) 8 ... 160А (change step 1А) for
MultiPRO-250
b) 10 ... 200А (change step 1А) for
MultiPRO-270
c) 12 ... 250А (change step 1А) for
MultiPRO-350
11) [Fr.P] current pulsation frequency = 5.0 Hz (by default)
a) 0.2 ... 500 Hz (dynamic change step 0.1 Hz...1 Hz)
12) [dut] pulse/pause ratio (duty cycle) - it is the percentage of the current pulse to the period of repetition of these pulses = 50% (by default)
a) 20 ... 80% (change step 5%)
TIG welding mode
0) [-2-] main display parameter CURRENT = 100A (by default)
a) 12 ... 25
0А (change step 1А) for
MultiPRO-250
b) 12 ... 27
0А (change step 1А) for
MultiPRO-270
c) 14 ... 3
50А (change step 1А) for
MultiPRO-350
1) [But] torch button mode = [2T] (by default)
a) [LIFT] - contact striking mode TIG-LIFT
b) [2T] - non-contact striking mode, TIG-2T button mode
c) [4T] - non-contact striking mode, TIG-4T button mode
2) [t.uP] current build-up time = 2 sec (by default)
a) 0.5 ... 25.0 sec (change step 0.1 sec)
3) [t.dn] current ramp-down time = 3 sec (by default)
a) 1.0 ... 25.0 sec (change step 0.1 sec)
4) [Pr.A] current preliminary
(pilot arc)
= 15А
(by default)
a) 12...40А (
change step
1А)
for MultiPRO-250
б) 12 … 40А (
change step
1А)
for MultiPRO-270
в) 14 ... 40А (
change step
1А)
for MultiPRO-350
5) [Po.A ] crater brewing current
= 20А
(by default)
a) 12...60А (
change step
1А)
for MultiPRO-250
б) 12 … 60А (
change step
1А)
for MultiPRO-270
в) 14 ... 60А (
change step
1А)
for MultiPRO-350
6) [t.uP] current rise time = 0,3 sec (by default)
a) 0,1 ... 5,0 sec (change step
0,1 сек.)
7) [t.dn current dowe time = 0,3 sec (change step)
a) 0,1 ... 5,0 sec (change step 0,1 sec)
8) [Po.P] current pulsation mode = OFF (by default)
a) ON
–
enabled
б) OFF –
disabled
9) [I.iP] pulse current = 100A (by default)
a) 12 ... 25
0А (change step 1А) for
MultiPRO-250
b) 12 ... 27
0А (change step 1А) for
MultiPRO-270
c) 14 ... 35
0А (change step 1А) for
MultiPRO-350
10) [I.PS] pause current = 100A (by default)
a) 12 ... 25
0А (change step 1А) for
MultiPRO-250
b) 12 ... 27
0А (change step 1А) for
MultiPRO-270
c) 14 ... 3
50А (change step 1А) for
MultiPRO-350
11) [Fr.P] current pulsation frequency = 10.0 Hz (by default)
a) 0.2 ... 500 Hz (dynamic change step 0.1 Hz...1 Hz)
12) [dut] pulse/pause ratio (duty cycle)
–
it is the percentage of the current pulse to the period of repetition of these pulses = 50% (by default)
a) 20 ... 80% (change step 5%)
MIG/MAG welding mode
0) [-3-] main displayed parameter VOLTAGE = 19.0 V (by default)
a) 12 ... 28.0V (change step 0.1V ) for MultiPRO-250
b) 12 ... 29.0V (change step 0.1V ) for MultiPRO-270
c) 12 ... 30.0V (change step 0.1V ) for MultiPRO-350
1) [But] torch button mode = [2T] (by default)