1.

  

GENERAL INFORMATION 

The PATON Feeder-15-2/15-4 digital wire feeder is designed to work in conjunction with an external welding 
source in semi-automatic welding mode. The power source supplies the welding current, and the wire feeder 
provides a stabilized feed of solid or cored wire into the weld pool.  
The feeder has its inverter source to power the motor, safety gas valve and control circuitry. What sets the 
PATON feeders apart is the very powerful, high-quality and sealed metal wire feeder and the KZ-2 EURO 
type connector, which has become a world standard, allowing the user to later change the torches as desired. 
A safety gas valve is built into the unit. 
When the feeder is in operation, its internal digital control board receives signals from the KZ-2 connector of 
the torch button and turns on the safety gas valve at the right moment, then, with a preset delay, signals to 
turn on the power supply, then turns on and stabilizes the speed of the wire feed motor. After the welding 
process is finished, every unit is turned off in reverse order with the necessary delays. Everything is set by 
default to optimum parameters. 
The unit is highly optimized to work with PATON sources and will require minimal time for user adaptation, 
as the mating spots for connectors and installation are already provided in the design. 

 

PARAMETERS 

Feeder-15-2 

Feeder-15-4 

Rated supply mains voltage 50Hz, V 

220 

220 

Rated input current from mains, А

 

0.25 

0.38 

Mains voltage variation limits, V 

180 

 260 

180 

 260 

Number of pressure rollers 

Control range of wire feed speed, m/min 

2.0 

 16.0 

2.0 

 16.0 

Continuous welding wire diameter, mm 

0.6 

 1.2 

0.6 

 1.6 

Maximum weight of wire coil, max. 

15 

15 

Wire-filling function 

yes 

yes 

Function of safety gas check 

yes 

yes 

Rated input power, VA 

55 

85 

Maximum input power, VA 

80 

115 

Operating temperature range 

–25 … +45ºС

 

–25 … +45ºС

 

Dimensions, mm (length, width, height) 

430х260х27

430х275х290

 

Weight without coil and accessories, kg 

7.5 

8.2 

 

Summary of Contents for Feeder-15-2

Page 1: ......

Page 2: ......

Page 3: ...allation of the welding torch 7 2 10 Wire filling 7 3 Operation of the wire feeder 8 3 1 Welding process cycle MIG MAG 2T 8 3 1 1 Torch button function 2T 9 3 2 Welding process cycle MIG MAG 4T 9 3 2...

Page 4: ...preset delay signals to turn on the power supply then turns on and stabilizes the speed of the wire feed motor After the welding process is finished every unit is turned off in reverse order with the...

Page 5: ...selecting functions of the wire feeder 7 KZ 2 EURO type connector for semi automatic torch connection 8 Power supply plug to the wire feeder 9 Lifting protective cover 10 Welding wire filler inlet 11...

Page 6: ...le Make sure that metal dust e g from sanding does not penetrate the machine WARNING The wire feeder can be life threatening after a hard fall Install on a stable hard surface 2 3 MAINS CONNECTION The...

Page 7: ...plication so it is not included in this manual for the wire feeder Look for it in the power supply manual The new generation of PATON power supply sources already includes all the features so the adap...

Page 8: ...n feeding of the wire Having opened the lifting cover 9 for wire filling lift the clamping beams upwards Plastic cams are used to unlock them The end of the wire is run through hole 10 in the rear wal...

Page 9: ...ines If you are a beginner and have no experience in setting the optimum wire feed rate for a particular product start with the average wire feed rate 6 0 8 0 m min and the average voltage on the sour...

Page 10: ...ime the function of smooth output to the welding mode in time t uP isactivated aswellas additional functions e g additional functions for example the last generation digital PATON sources have a pulse...

Page 11: ...this button is locked To unlock it it is necessary to hold it pressed for more than 3 5 seconds When unlocked horizontal bars will appear on the display indicating that the function menu is unlocked A...

Page 12: ...RATOR OPERATION MODE Wire feeder consumes extremely low power usually not exceeding 100W so the main condition is that the output voltage of the generator must not exceed the permissible limits of 180...

Page 13: ...must be eliminated immediately USER OBLIGATIONS The user is obliged to allow only those persons to work on the machine who Are familiar with the basic safety instructions and have been trained in the...

Page 14: ...TIONAL warrants that the wire feeder will operate properly if the user follows the operating storage and transportation conditions WARNING There is no free warranty service if the welding machine is m...

Page 15: ...mponents and mechanical parts The main warranty also does not cover damaged external parts of the equipment that are subject to physical contact and accessories consumables which must be claimed withi...

Page 16: ...MAG 12 ACCEPTANCE CERTIFICATE PATON Feeder 15 2 15 4 inverter feeding unit Serial number _______________BP recognized as serviceable Sale date _____ ________________20____ Seal here _________________...

Page 17: ..._________________________________________________________ Date of acceptance for repair _____ _________________20____ __________________ signature Signs of inoperability ______________________________...

Page 18: ...__________ ____________________________________________________________________ ____________________________________________________________________ Date of acceptance for repair _____ _______________...

Reviews: