38
Wall mount Signal Tower Instruction Manual
8. Operation
Example Transmission
・
Signal Tower: "Tier 1: Light on", "Tier 2 and 3: Flashing (slow)", "Tier 4: Light off"
・
Buzzer: Pattern 1
Product
Category AB
ID S
Unused
Data Size
Data Area (6 bytes)
1
2
3
4
5
6
41H
42H
53H
00H
00H
06H
01H
02H
02H
00H
00H
01H
8.1.2 Detailed Motion Control (All-tiers Flashing) Command
・
You can specify and control the color and pattern of each tier of the Signal Tower and the buzzer pattern in the
data area.
・
Operates buzzer volume set up in Web Screen.
Request Command
・
Transmission Data Format
Product
Category
*1
ID
*2
Unused
Data Size
Data Area
*3
(7 bytes)
1
2
3
4
5
6
7
A
B
D
–
–
–
Signal
Tower
color
(Tier 1)
Signal
Tower
color
(Tier 2)
Signal
Tower
color
(Tier 3)
Signal
Tower
color
(Tier 4)
(unused)
Signal
Tower
pattern
Buzzer
pattern
41H
42H
44H
00H
00H
07H
00H
1 byte 1 byte 1 byte
1 byte
2 bytes
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
* 1 This product's product category is "AB".
* 2 Use "D" for ID.
* 3 Data area is as follows.
Type
Value
Description
Type
Value
Description
Type
Value
Description
Signal
Tower
color
00H
Light off
Signal
Tower
pattern
00H
No flashing
Buzzer
pattern
00H
Stop
01H
Red
01H
Flashing (slow)
01H
Buzzer pattern 1
02H
Amber
02H
Flashing
(medium)
02H
Buzzer pattern 2
03H
Lemon
03H
Flashing (fast)
03H
Buzzer pattern 3
04H
Green
04H
Single flash
04H
Buzzer pattern 4
05H
Cyan
05H
Double flash
05H
Buzzer pattern 5
06H
Blue
06H
Triple flash
06H
Buzzer pattern 6
07H
Purple
07H
Pulse
(bright and dark)
07H
Buzzer pattern 7
08H
Pink
08H
Right chase light
08H
Disabled,
ACK response
09H
White
09H
Left chase light
09H
No change