background image

Electric I&O Manual     

IM111116 RL:2A  AUG 2018

6

 

PART NUMBER 

WATTS  MOUNTING HEIGHT 

AVERAGE 

COLD  

PROTECTED

 

 

ESD/ELD-4039-24  4,000  8' - 12' [2.4 m - 3.7 m]  8' x 10' [2.4 m x 3.0 m]  6' x 8' [1.8 m x 2.4 m]  10' x 12' [3.0 m x 3.7 m]

  ESD/ELD-5039-24  5,000  8' - 12' [2.4 m - 3.7 m]  9' x 10' [2.7 m x 3.0 m]  7' x 8' [2.1 m x 2.4 m]  11' x 12' [3.4 m x 3.7 m]

  ESD/ELD-6061-24  6,000  10' - 14' [3.0 m - 4.3 m]  11' x 11' [3.4 m x 3.4 m]  10' x 10' [3.0 m x 3.0 m]  12' x 12' [3.7 m x 3.7 m]

DUAL ELEMENT TYPICAL AREA COVERAGE - feet [m]

SINGLE ELEMENT TYPICAL AREA COVERAGE - feet [m]

 

PART NUMBER 

WATTS  MOUNTING HEIGHT 

AVERAGE 

COLD  

PROTECTED

 

 

ES/EL-1533-20  1,500  6' - 8' [1.8 m - 2.4 m]  5' x 5' [1.5 m x 1.5 m] 

3' x 3' [.91 m x .91 m]  7' x 7' [2.1 m x 2.1 m]

  ES/EL-2039-24  2,000  7' - 9' [2.1 m - 2.7 m]  6' x 6' [1.8 m x 1.8 m] 

4' x 4' [1.2 m x 1.2 m]  8' x 8' [2.4 m x 2.4 m]

  ES/EL-2539-24  2,500  7' - 9' [2.1 m - 2.7 m]  7' x 7' [2.1 m x 2.1 m] 

5' x 5' [1.5 m x 1.5 m]  9' x 9' [2.7 m x 2.7 m]

  ES/EL-3061-24  3,000  7' - 9' [2.1 m - 2.7 m]  8' x 8' [2.4 m x 2.4 m] 

6' x 6' [1.8 m x 1.8 m]  10' x 10' [3.0 m x 3.0 m]

  ES/EL-4061-24  4,000  8' - 11' [2.4 m - 3.4 m]  10' x 10' [3.0 m x 3.0 m]  8' x 8' [2.4 m x 2.4 m]  12' x 12' [3.7 m x 3.7 m]

GENERAL NOTES

electricSchwank [ES/ESD] and EL/ELD Series heaters are furnished with wall/ceiling mount swivel brackets.  

These brackets may be discarded when the heater is suspended with chains, or other special bracketing.
See 'Specifications' page 2 for full listing of models, voltages, and amperages. At times, especially when the 

mounting height might be quite low, a greater quantity of smaller heaters can help prevent overheating.
Heaters up to 15 AMPS can be controlled with a simple INF controller. This low cost controller, which is actually  

an infinite switch, gently pulses the heat on and off at regular intervals when not on full power.
Dual Element Heaters can be wired with Duplex/Stack Switch, which enables the ability to operate each element 

independently, providing for two-stage [half power/full power] capability.
For best comfort heat, heat from two sides rather than from just one side. However, there are site conditions where 

this is not practical.
Coverage areas indicated above are typical approximate dimensions and will vary depending on outdoor 

temperature, wind velocity, and personal comfort levels.
Indoor and well-protected environments will generally exceed the average chart values. Heaters will provide less 

than average coverage in extremely cold/windy conditions.

MAINTENANCE INSTRUCTIONS

Before performing any maintenance or cleaning, 

power must be disconnected

 and the heater cool to touch. 

Heater housing, reflectors, and heating element can be rinsed with a hose or wiped down with isopropyl 

alcohol, acetone, or glass cleaner. Use a clean, scratch-free rag or paper towel. Any oxidation, surface rust, or 

discoloration can be removed with a stainless steel cleaner or metal polish on the bare metal surface.
Make sure all water, solvents, or cleaners are removed and the heater is dry before reconnecting the power.

Summary of Contents for electricSchwank Series

Page 1: ...arranty 8 For warranty purposes and ordering replacement parts record the following information Model _________________________________________ Serial ____________________________________________ Date...

Page 2: ...rom ceiling and do not install less than 8 2 4 m from floor Ceiling Mounting Do not install heater closer than 18 45 7 cm from adjacent walls and 6 15 2 cm from ceiling and do not install less than 8...

Page 3: ...H WIRING FOR OPTIONAL 120V 240V CONTROLS Connect power with flexible conduit or appropriate cord to allow heater to be swiveled Junction Box on top of the heater has a gasket side access cover The Jun...

Page 4: ...Manual IM111116 RL 1B May 2017 MINIMUM 18 45 7 cm FROM SIDE MINIMUM 18 45 7 cm FROM SIDE 96 244 cm MINIMUM HEIGHT FROM FLOOR 6 3 8 15 2 cm LEVEL HERE 4 WALL 60 MAX A I M P O I N T CEILING 60 MAX MOUNT...

Page 5: ...JE 0557 24 58 1 5 m 4000 240 ES 4061 24 EL 4061 24 REPLACEMENT PARTS PART NUMBER PART DESCRIPTION QUANTITY JE 0570 XX Single Element End Reflector Set of 2 1 JE 0571 XX Dual Element End Reflector Set...

Page 6: ...erages At times especially when the mounting height might be quite low a greater quantity of smaller heaters can help prevent overheating Heaters up to 15 AMPS can be controlled with a simple INF cont...

Page 7: ...or weather cover whenever possible Even though heater is all weather construction it will last longer and look better if it is protected from rain and snow Angle fixture 30 to 60 from horizontal face...

Page 8: ...t on the rating plate The Manufacturer shall not be liable for any default or delay in performance by its warranty caused by any contingency beyond its control including war government restrictions or...