2

MOUNTING HEIGHT/CLEARANCES

READ ALL INSTRUCTIONS BEFORE USING HEATER

Unit may be a source of possible shock. NEVER attempt to service heater without disconnecting its power source.
Source of possible ignition - maintain clearances from combustible materials.

 WARNING:

 If not installed, operated and maintained in accordance with the manufacturer’s instructions, this 

product can expose you to chemicals including nickel, which are known to the State of California to cause cancer. 
For more information go to 

www.P65Warnings.ca.gov

.

High Temperature, risk of fire, keep electrical cords, drapery, furnishings and other combustibles at least 3' [0.9m] 
from the front of heater and away from sides and rear.

  

Wall-Mounting:

 Do not install heater closer than 18" [45.7 cm] from adjacent walls and 6" [15.2 cm] from ceiling 

and do not install less than 8' [2.4 m] from floor.

    

Ceiling-Mounting:

 Do not install heater closer than 18" [45.7 cm] from adjacent walls and 6" [15.2 cm] from 

ceiling and do not install less than 8' [2.4 m] from floor.

-  For heater angled greater than 30° from horizontal, use spacers above mounting brackets to provide 
  minimum 6” [15.2 cm] clearance above heater to combustible ceiling.

  Adjacent Heaters to be installed no less than 3' [0.9 m] apart.

  Do NOT operate within 25' [7.6 m] of flammable/explosive material.

  Never block heater.

  Heaters greater than 240 Volts are for “Commercial Use Only. Risk of fire. Do not use as a residential or 

household heater.”

  A means for disconnection of the appliance must be incorporated in accordance with local wiring codes.

  Do not use if the heating element is damaged or cracked.

“IMPORTANT INSTRUCTIONS”

“SAVE THESE INSTRUCTIONS”

CLEARANCE FROM HEATER SURFACES TO COMBUSTIBLES:

WARNINGS

CAUTION

MIN. 6" [15.2 CM] 

CLEARANCE 

BEHIND HEATER

MIN. 18" [45.7 CM] 

FROM SIDES AND 

ENDS OF HEATER

MIN. 36" [91.4 CM] 

FRONT / BELOW 

HEATER

Summary of Contents for electricSchwank Series

Page 1: ...arranty 8 For warranty purposes and ordering replacement parts record the following information Model _________________________________________ Serial ____________________________________________ Date...

Page 2: ...rom ceiling and do not install less than 8 2 4 m from floor Ceiling Mounting Do not install heater closer than 18 45 7 cm from adjacent walls and 6 15 2 cm from ceiling and do not install less than 8...

Page 3: ...H WIRING FOR OPTIONAL 120V 240V CONTROLS Connect power with flexible conduit or appropriate cord to allow heater to be swiveled Junction Box on top of the heater has a gasket side access cover The Jun...

Page 4: ...Manual IM111116 RL 1B May 2017 MINIMUM 18 45 7 cm FROM SIDE MINIMUM 18 45 7 cm FROM SIDE 96 244 cm MINIMUM HEIGHT FROM FLOOR 6 3 8 15 2 cm LEVEL HERE 4 WALL 60 MAX A I M P O I N T CEILING 60 MAX MOUNT...

Page 5: ...JE 0557 24 58 1 5 m 4000 240 ES 4061 24 EL 4061 24 REPLACEMENT PARTS PART NUMBER PART DESCRIPTION QUANTITY JE 0570 XX Single Element End Reflector Set of 2 1 JE 0571 XX Dual Element End Reflector Set...

Page 6: ...erages At times especially when the mounting height might be quite low a greater quantity of smaller heaters can help prevent overheating Heaters up to 15 AMPS can be controlled with a simple INF cont...

Page 7: ...or weather cover whenever possible Even though heater is all weather construction it will last longer and look better if it is protected from rain and snow Angle fixture 30 to 60 from horizontal face...

Page 8: ...t on the rating plate The Manufacturer shall not be liable for any default or delay in performance by its warranty caused by any contingency beyond its control including war government restrictions or...