PST900/XS Wiring Detail
Output Junction Box
Input Junction Box
LE Input Junction Box
Recommended interconnection cable (Remote Mount)
2
4 Core 2.5 mm Max Length 80 Metres
Recommended interconnection cable (Driver On Board)
2
4 Core 1 - 1.5 mm Max Length 5 Metres
AC Input can be split into two channels if
individual switching is desired
PST900/XS Light Engine
Junction Box
The PST 900/XS Light Engine module is designed
solely for use with its associated PDM2I60-PS900
Driver Module.
DO NOT CONNECT TO ANY OTHER SUPPLY
CAUTION: DC Input polarity critical. Continuous
or momentary reverse polarity will irreparably
damage the LED COB and void warranty
PLED18-900-8
BROWN
BLUE
+
-
OUTPUT
1
BROWN
BLUE
+
-
OUTPUT
2
Control 1
Control 2
BROWN
BLUE
DRIVER 1
INPUT
1
DRIVER 2
INPUT
2
GRN/YEL
ACTIVE
NEUTRAL
EAR
TH
BROWN
BLUE
GRN/YEL
M20 x 1.5mm
M25 x 1.5mm
BLK/WHT(V
)
AUX
PURP(DIM +)
GRY(DIM -)
DIM2 -
DIM2 +
2Vaux
BLK/WHT(V
)
AUX
PURP(DIM +)
GRY(DIM -)
DIM1 -
DIM1 +
1Vaux
2+
2-
1+
1-
DIN Rail
Ground
All junction boxes are designed to facilitate
25 x 1.5 mm & 20 x 1.5 mm liquid tight
conduit fittings. Any fittings employed must
conform to IP67
RED
BLCK/WH
INPUT
1
+
-
INPUT
2
+
-
RED/YEL
1+
1
-
2+
2
-
BLK/YEL
2020 Pled Australia Pty Ltd. All rights reserved. For informational purposes only
PATHFINDER
LED