28
Unit Setup
...Port Setup
On/Off selection list
The options in this menu are used
to set how the coverage area
recording is turned on/off when in
the job screen.
Turning the trace recording on
and off when turning in the head
land can give a more accurate
coverage area reading for the
recorded data.
N.B.
On/Off type will be set automatically if an implement that has been setup in
WebTrack has been selected from the Implement option in Recording Details.
Switch -
(On/Off in WebTrack)
– This type uses a switch which is connected to
the unit that creates an electrical connection when in the on position, to turn the
coverage area recording on and off.
On Screen
- (Use Arrows in Webtrack)
– When this type is set the coverage
area recording can be turned on and off by the operator using the Recording on/
off button on the guidance screen.
AlwaysOn
- This sets the coverage area recording to continually record and can
not be turned off.
SwitchReversed -
(On/Off Reversed in WebTrack)
– This type uses a switch
which is connected to the unit that creates an electrical connection when in the
off position, to turn the coverage area recording on and off.
Controller
-
This option is used when the BlackBox is connected to an
implement controller via a data cable for turning the coverage area recording
On/Off. For example when the implement is working the trace will be on and
when not working the trace will be off.
Communications must be established between the BlackBox and Controller for
this system to work (see VRT Options on page 29 for setup information).
Please Note:
Some controllers do not have the facility to return an on/off signal.