The set up of the filters and specially their frequency placement can also be done with the use of the mouse,
just activating the “Show Cursor” function, pressing the related button on the left bottom of the frequency
response Graphic.
Once the all 5 available cursor are shown on the Frequency Response graphic, just selecting anyone of them
with the mouse's arrow and maintaining the mouse's click pressed, it is possible to move and place the
selected cursor on the desired frequency and with the desired gain.
For setting the filter's Q, still need to enter the desired value directly in the dedicated box in the filters' editing
main sub-frame.
In order to see what's the “Phase” response of the channel once set up the all filters of the EQ, it is possible,
selecting the Phase choice on the top right of the Graphic window, to turn the graphic in “Phase Response
Graphic”:
Step dB
– this simple function is allowing to set the resolution in dB of the Grid Lines of the Graphic displaying
the Magnitude response of the equalization.
The resolution can be set in a range from 5dB up to 50dB, by steps of 5dB.
Offset dB
– here can be set an “offset” in dB in visualizing the Magnitude response of the equalization.
Once added a positive offset, more space is given in the graphic to the visualization above the 0dB, when a
negative offset is added, more space is given to the visualization below the 0dB.
The offset can be set in a range from 10dB up to -120dB, by steps of 10dB.
Level [dB]
– from this sub-frame it is possible to set the Output Channels Level from -127dB up to +18dB.
Pressing the “Bypass” button at the bottom of the Level slider, the currently set level will be skipped and the
output level will be set to 0dB.
Phase
– when this check box is “unchecked” the processed signal is left with its original phase.
When the check box is “checked”, then the original phase of the signal is inverted of 180Deg.
Delay
– from this sub-frame it is possible to set the Output Channels Delay Time from 000.0000mS (0 meters)
up to 380.998mS (129.53932 Meters), by steps of 1mS (Adj arrows) or 20.8uS (Fine arrows).
23