background image

15

Servicing

Restrict Field Service to the Following

CHECKING THE ENERGY LEVEL OF THE BATTERY

RECHARGING THE BATTERY

CHECKING THE FUEL CELL AND METERING VALVE

REPLACING THE FUEL CELL

CLEANING THE AIR FILTER

CLEARING A JAM

 CLEANING THE TOOL (See cleaning manual)

Attempts to go beyond these procedures could result in
serious personal injury or damage to the Paslode Cordless
Finish nailer and voiding the warranty.

There are certain problems you may encounter when you
are using the Cordless Finish nailer that you will be able to
correct on the work site. The following field service procedures
are the only service procedures you should attempt. Anything
else that may appear wrong with the Cordless Finish  nailer
should only be diagnosed and repaired by a fully trained
service technician. If you have any reason to believe that
your problem is beyond the service procedures in this
manual, contact your Paslode

®

 representative immediately.

Fuel Cell Check

If the Paslode Cordless  Finish nailer's fan operates and the
indicator light is green, but the tool will not cycle or does not
drive fasteners completely, check the fuel cell. With the fuel
cell out of the tool, check to see if the cell still contains fuel
and that the metering valve is working. To determine if there
is any fuel left in the fuel cell, hold in the upright position and
simply place the metering stem against a solid object, and
gently push about three or four times. A small amount of fuel
should be released each time.

           DANGER

Never perform this test near an open flame or sparks,
while smoking, or where the fuel may get into your eyes.

If fuel is not released with each operating of the metering
valve, this indicates that there is no more fuel left in the
cylinder and it must be replaced. Dispose of the empty fuel
cell properly.

Clearing a Jam

A typical problem you may encounter is having a jammed
fastener. Because of the unique design of the Cordless
Finish Nailer, clearing a jammed fastener is easy:
1.

Remove the battery.

2.

Pull follower back until it latches with rail cover.

3.

Push latch, releasing front guide. Pivot front guide
forward.

4.

Clear jam, and push driver blade back up to its normal
position.

5.

Close front guide and latch it.  Check that work contacting
element is free.

6.

Release follower.

Battery Check

Periodically check on the  battery indicator light - the  light
in the handle of the  Paslode Cordless  Finish  nailer. When
encountering a problem, the first step should always be to
make sure the battery has enough energy to operate the
tool.

When the work contacting element is depressed on work
piece, the fan motor will turn on and the blinking green
indicator light will turn solid green. If the indicator light  blinks
red or glows red, recharge the battery.

           DANGER

Never attempt any maintenance of the Paslode Cordless
Finish nailer without first removing the fuel cell and
battery. Maintenance should be started only after the
tool is completely inoperative.

Summary of Contents for IM250 II

Page 1: ...o have all operators and service personnel read and understand this manual OPERATING MANUAL IM250 F 16 II CORDLESS FINISH NAILER Model IM250 II Part No 900400 Cordless 16 Gauge Finish Nailer Printed i...

Page 2: ...Fasteners and Applications 14 Servicing 15 Troubleshooting 17 The battery charger system meets all safety requirements for power tools is a trademark Paslode An Ilinois Tool Works Company 888 Forest...

Page 3: ...ts and accessories will be free from defects in material and workmanship for the period shown below after the date of delivery to the original user ONE YEAR LIMITED WARRANTY A one year warranty will a...

Page 4: ...ts to load and control the specfic fastener for the Cordless Finish nailer Specifications Dimensions Weight 5 lbs 1oz Height 12 1 2 nches Length 11 3 4 inches Cycle Rate Intermittent Operation 2 to 3...

Page 5: ...ombustible materials such as flammable chemicals adhesives gasoline or solvents WARNING Do not attempt to operate this tool until you have read and understood all safety precautions and manual instruc...

Page 6: ...y 11 OPERATE THE TOOL ONLY ON THE WORKPIECE 1 Eye protection must meet the requirements of ANSI Standard Z87 1 and should have side shields for increased protection 2 NEVER ASSUME THE TOOL IS EMPTY Ne...

Page 7: ...reach since tool recoil may cause a loss of balance Always be aware of edges and drop offs when nailing on rooftops and other high locations Keep them in full view WARNING Only persons who have read...

Page 8: ...ubjected to temperatures above 120 F 49 C 5 Do not incinerate battery 6 Do not use a defective battery charger one that over heats and or smokes when plugged in 7 Do not immerse the battery in water C...

Page 9: ...quirerecharging IMPORTANT Should your battery terminals become corroded and cause poor electrical contact clean the terminals using a soft cloth Battery Indicator Light The illustration is a close up...

Page 10: ...that all the fuel is used and that the Paslode Cordless Finish nailer can operate in any position Because of this container within a container design you might hear the sound of fluid when shaking the...

Page 11: ...a fuel cell 1 Press downward on the front side of the valve stem side until it seats 2 Press downward on the rear side of the valve until it seats 3 The valve is now completely seated onto the fuel c...

Page 12: ...will notice a yellow adapter at the top of the cylinder pocket As shown in the illustration this adapter is designed to ensure that the metering valve stem is properly aligned with the small hole or o...

Page 13: ...iods keep the fuel and tool out of direct sunlight and in surroundings where temperatures will not exceed 120 F 49 C After extended periods of continuous use it may be necessary to cool the Impulse mo...

Page 14: ...bustion powers piston assembly driving fastener LIFT TOOL RELEASE TRIGGER Combustion chamber opens Fan exhausts hot gases and cools internal components Turn adjustment knob in either direction DANGER...

Page 15: ...6 Series nails They are made from 16 gauge galvanized wire and are entirely coated witrh Pas Kote for improving holding power Fasteners are collated into strips of 50 for easy loading Fasteners PART N...

Page 16: ...tem against a solid object and gentlypushaboutthreeorfourtimes Asmallamountoffuel should be released each time DANGER Never perform this test near an open flame or sparks while smoking or where the fu...

Page 17: ...ol 2 Dispose of all empty fuel cells Remember to dispose of these cells where they will not be found by children crushed punctured or burned When you get home 1 Place the battery in its charger if it...

Page 18: ...MPTOM POSSIBLE PROBLEMS SERVICE Normal Stage of Operation Fan does not run tool indicator light is blinking red or solid red Fan does not run or runs slower than normal tool indicator light is solid r...

Page 19: ...tened changes Use only fasteners meeting Paslode specifications Check Fasteners and Applications section for fastener types and sizes recommended for use in Cordless tool Position follower behind fast...

Page 20: ...mber of each Paslode tool contains information about the tool and the fasteners that are used with it The following example illustrates the information contained in this tool model number IMPULSE Tech...