background image

®

Technical Support

 PS

-

3213

5

013-14935B

Suggestions

SE-6478 Ergopedia Optics System

SE-6481 Ergopedia Light, Color and Optics Teacher 
Resources

EX-5547A Light Intensity vs. Distance Experiment

Solar Panel Efficiency

Photosynthetic activity at different light levels or 
colors

Transpiration at different light levels

Modeling day and night

Modeling seasons

UV protection of different materials

Technical Support

For assistance with any PASCO product, contact 

PASCO at:

The Reference Guide will be updated periodically. For 

the latest revision of this Reference Guide, visit the 

PASCO Web site at

www.pasco.com/manuals 

and enter the product number, PS-3213, in the text 

window.

Replacement Parts

For information about possible replacement parts, 

contact Technical Support:

Coin-cell Battery Replacement Pack (10 pack) - 

PS-3504

Limited Warranty

For a description of the product warranty, see the PASCO catalog. For 

more information visit www.pasco.com/legal

Copyright

This PASCO scientific 

Reference Guide

 is copyrighted with all rights 

reserved. Permission is granted to non-profit educational institutions for 

reproduction of any part of this manual, providing the reproductions are 

used only in their laboratories and classrooms, and are not sold for profit. 

Reproduction under any other circumstances, without the written consent 

of PASCO scientific, is prohibited. Version 23-07-2016.

Trademarks

PASCO, PASCO scientific, PASCO Capstone, PASPORT, and 

SPARKvue are trademarks or registered trademarks of PASCO scientific, 

in the United States and/or in other countries. All other brands, products, 

or service names are or may be trademarks or service marks of, and are 

used to identify, products or services of their respective owners. For more 

information visit www.pasco.com/legal.

FCC Statement

This Class A digital device complies with part 15 of the FCC Rules. 

Operation is subject to the following two conditions: (1) This device may 

not cause harmful interference, and (2) this device must accept any 

interference received, including interference that may cause undesired 

operation.

CE Statement

This device has been tested and found to comply with the essential 

requirements and other relevant provisions of the applicable EU 

Directives.

Product End of Life Disposal Instructions:

This electronic product is subject to disposal and recycling regulations that 

vary by country and region. It is your responsibility to recycle your 

electronic equipment per your local environmental laws and regulations to 

ensure that it will be recycled in a manner that protects human health and 

the environment. To find out where you can drop off your waste equipment 

for recycling, please contact your local waste recycle/disposal service, or 

the place where you purchased the product.
The European Union WEEE (Waste Electronic and 

Electrical Equipment) symbol (to the right) and on the 

product or its packaging indicates that this product 

must not be disposed of in a standard waste 

container.

Battery Disposal Instructions:

Batteries contain chemicals that, if released, may affect the environment 

and human health. Batteries should be collected separately for recycling, 

and recycled at a local hazardous material disposal location adhering to 

your country and local government regulations. To find out where you can 

drop off your waste battery for recycling, please contact your local waste 

disposal service, or the product representative.
The Lithium Polymer (Li-Poly) rechargeable battery used in this product is 

marked with the International symbols to indicate the need for the 

separate collection and recycling of batteries

.

Address:

PASCO scientific

10101 Foothills Blvd.

Roseville, CA 95747-7100

Phone:

+1 916 462 8384 (worldwide)

8700-772-8700 (U.S.)

Web:

www.pasco.com/support

Email:

[email protected]

Summary of Contents for PS-3213

Page 1: ...n watts per square meter The Ambient Light Aperture also measures UVA ultra violet A and UVB ultra violet B allowing ultra violet index UVI to be calculated PASCO Data Collection Software will display...

Page 2: ...ttery Status LEDs operate as follows depending on the type of connection For a wireless Bluetooth connection Logging PASCO wireless sensors can either stream live data to a compatible device for real...

Page 3: ...tant to making the sensor simple and always ready to use so all of the PASCO wireless products are designed for long battery life For example the sensor turns itself off after a few minutes of inactiv...

Page 4: ...e for more information about experiments Or enter Light into the Search window at www pasco com Measurements The Spot sensor measures relative light levels in red green blue and white The Ambient sens...

Page 5: ...his Class A digital device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept an...

Page 6: ...The Mac Mini and MacBook Air were updated with Bluetooth SMART support in 2011 The MacBook Pro was updated in 2012 The Mac Pro that debuted in December 2013 has Bluetooth SMART support Exception Befor...

Page 7: ...n with wave lengths between 315 and 400 nm UVB Ultraviolet B is ultraviolet radiation with wave lengths between 290 and 320 nm comprising less than 1 per cent of the ultraviolet radiation that reaches...

Page 8: ...1240 a PASCO Basic Optics Light Source OS 8470 a PASCO Track and PASCO data collection software The illustration shows the equipment setup Equipment setup for measurement of light intensity versus dis...

Reviews: