background image

®

M o t i o n   S e n s o r

  P S - 2 1 0 3 A

3

To Aim the Motion Sensor at an Object

1.

Set the range switch to the short range (

) or long 

range (

) setting.

Select 

 for measuring a cart on a track. 

Select 

 for measuring most other objects.

2.

Arrange the Motion Sensor and object so that the Motion 
Sensor's transducer faces the object.

The object should be at least 15 cm from the transducer.

If the object will move, it should move directly toward 
or away from the Motion Sensor.

Aim the motion sensor slightly up to avoid detecting the 
tabletop.

3.

Remove objects that may interfere with the measurement. 
These include objects between the sensor and target object, 
either directly in front of the sensor or to the sides.

Data Collection

PASCO Capstone

1.

Click 

Record

The Motion Sensor starts clicking. If a target is in range, the 
target indicator flashes with each click. PASCO Capstone 
starts collecting and displaying data.

2.

Click 

Stop

 to stop data collection.

SPARK SLS

1.

Press 

Start

 to begin collecting and recording data.

2.

Press 

Stop

 to end data collection.

Xplorer GLX (Standalone)

1.

Press 

s

The Motion Sensor starts clicking. If a target is in range, the 
target indicator flashes with each click. The GLX starts 
collecting and displaying data.

2.

Click 

s

 to stop data collection.

3.

Click 

s

 again to start recording data in a new data run.

Sensor Configuration

To View Velocity and Acceleration

The Position measurement appears by default. You can also 
enable Velocity and Acceleration measurements.

In the PASCO Capstone graph, click the label of the vertical 
axis and select 

Velocity

 or 

Acceleration

 from the Measure-

ments Menu.

In the SPARKvue graph, press the Graph Tools icon to open 
the Graph Tools palette. Press the Display Properties icon to 
open the Line Graph Properties screen. Press 

Velocity

 or 

Acceleration

 and then press 

OK

.

On the GLX while viewing any display screen, press 

c

 

twice

 to open a data source menu. Select 

More

 to expand the 

menu. Select 

Velocity

 or 

Acceleration

.

To Change the Sample Rate

In PASCO Capstone, change the 
Motion Sensor sampling rate by 
clicking the up or down arrows 
in the Sample Rate Control tool.

In SPARKvue, press the Sampling Options 
icon. Select the Sampling Mode, Sample 
Rate, and Sample Rate Unit in the Sampling 
Options screen, and then press OK.

On the GLX, press 

h

 + 

I

 to open the Sensors screen. 

Highlight the 

Sample Rate

 setting and press 

+

or

-

.

The normal range of sampling rates is between 1 Hz and 50 Hz. 
At the default rate, the Motion Sensor can measure distance up to 
8 m. The maximum distance decreases with increasing sample 
rate. At very high sample rates (between 50 Hz and 250 Hz), the 
maximum distance is less than 2 m.

Display 

Properties icon

Graph 

Tools icon

Motion Sensor 

Sample Rate

Sampling 

Options icon

Reviews: