The injector in this appliance is not removable and is assembled by the manufacturer. It is forbidden
to convert the injector from one gas pressure to another.
•
Do not connect the gas cylinder directly to the appliance without a regulator. Only use the type of
gas and the type of cylinder specified in the instructions.
Only use a regulator (complies with EN16129:2013 and the national regulation) of the correct
pressure corresponding to the appliance category.
•
Use a 30 mbar regulator for butane/propane of the category l3B/P(30).
•
Use a 30 mbar regulator for butane of the category l3+(28-30/37).
•
Use a 37 mbar regulator for propane of the category l3+(28-30/37).
•
Use a 50 mbar regulator for butane/propane of the category l3B/P(50).
PLEASE READ THE FOLLOWING SAFETY GUIDELINES CAREFULLY BEFORE OPERATION.
•
Do not use the patio heater indoors as it may cause personal injury or property damage.
•
This outdoor heater is not intended to be installed on recreational vehicles and/or boats.
•
lnstallation and repair should be done by a qualified service person.
•
lmproper installation, adjustment or alteration can cause personal injury or property damage.
•
Do not attempt to alter the unit in any way.
•
Never replace or substitute the regulator with any regulator other than the factory-suggested
replacement.
•
Do not store or use gasoline or other flammable vapors or liquids in the heater unit.
•
The entire gas system, hose, regulator, pilot and burner should be inspected for leaks and damage
before use, at least annually by a qualified service person.
•
All leak tests should be done with a soap solution. Never use an open flame to check for leaks.
•
Do not use the heater until all connections have been leak tested.
•
Turn off the gas valve immediately if a gas smell is detected. Turn the cylinder valve OFF.
»
lf the leak is at the hose/regulator connection: tighten the connection and perform another leak
test. lf bubbles continue to appear, the appliance should be returned to the manufactorer.
»
lf the leak is at the regulator / cylinder valve connection: disconnect, reconnect, and perform
another leak test. lf bubbles continue to appear after several attempts, the cylinder valve is
broken and the appliance should be returned to the manufactorer.
•
Do not transport the heater while in operation.
•
Do not move the heater after it has been turned off until the temperature has cooled down.
•
Keep the ventilation opening of the cylinder enclosure free and clear of debris.
•
Do not paint the radiant screen, control panel or top canopy reflector.
•
The control compartment, burner and circulation air passage ways of the heater must be kept
clean.
•
Frequent cleaning is required.
•
The gas tank should be turned off when the heater is not in use.
GAS HEATER | MANUAL
6
EN
Summary of Contents for MAGMA
Page 2: ......
Page 3: ...EN 4 21 NL 22 39 FR 40 57 DE 58 75 INHOUD CONTENT CONTENU INHALT...
Page 76: ......