background image

PUMP DISASSEMBLY/ASSEMBLY

Hazardous voltage.

Can shock, burn, or kill.

Disconnect

all power to pump before beginning this
operation.

1. Pull disconnect switch. Disconnect

power lines from pressure switch.

2. Open faucets or lines and release

all pressure in the system before
proceeding.

3. Remove the two cap screws holding

the pump to the flange adapter.
Don’t disturb the piping in the well.

4. Remove the flange adapter gasket

and scrape the surfaces clean.

5. Leaving the tubing in place,

unscrew and remove the straight
barbed fitting at the pressure switch.

6. Draw a line down the side of the

pump with a marker to help align-
ment during reassembly. Mark the
pump from the motor to the base
volute (see Figure 1).

7. Turn the pump upside down on the

bench and block it. Remove the four
cap screws from the base. With a
mallet, tap upward on the base to
loosen it. Lift the base off of the
intermediate volute (see Figure 2). 

8. To reduce the chance of dropping

the pump onto your foot, lay it down
on the bench; block it so it won’t roll.

9. Hold the motor shaft with pliers or

vice grips through the opening in
the pump adapter. Unscrew the
impeller nut off the end of the shaft
(see Figure 3).

10. The impellers are keyed to the shaft

and do not unscrew. Insert two screw
drivers on opposite sides under the
exposed impeller and pry the impeller
off (Figure 4) to remove it.

11. CAREFULLY tap a small screw-

driver or thin bladed chisel in
between the intermediate volute
and the pump adapter in two or
three places around the pump to
separate the castings (Figure 5). Do
not mar the sealing surfaces; do not
break pieces out of the adapter or
volute – the castings are easily
damaged.

12. Remove the intermediate volute and

slide the impeller spacer off of the
shaft.

13. Remove the impeller. Don’t disturb

the shaft keys if you are only replac-
ing the seal.

14. Rotate the seal spring retainer cup

so that the slot lines up with the
shaft keys; remove the cup and
spring.

15. Remove the two cap screws holding

the adapter bracket to the motor.

16. With two screwdrivers on opposite

sides of the pump, carefully pry the
pump adapter away from the motor.
This will pull the seal off of the
motor shaft. Use caution to make
sure that the ceramic seal does not
dig into the shaft and scratch the
shaft’s sealing surface.

INSTALLATION OF NEW SEAL

1. Clean all gasket surfaces thorough-

ly before reassembly. Clean the
seal bore cavity in the pump
adapter.

2. Wet the rubber seat ring with soapy

water and push the stationary part
of the seal into the seal bore cavity.
Use a piece of 1" pipe pressing on a
cardboard washer (to prevent dam-
aging seal surface) as a press.
Make sure that the seal half is fully
seated in the seal bore cavity.
Remove the cardboard once the
seal is in place.

(

continued)

P2O-27 (8/27/07)

For further operating, installation, or maintenance assistance:

1-877-PUMP-P2O 

(1-877-786-7726)

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Vertical Multistage Pump 

Overhaul Kit

FPP1650 and FPP1657

Phone: 1-877-PUMP-P2O (877-786-7726) 
Web Site: http://parts2o.com

Summary of Contents for FPP1650

Page 1: ...el in between the intermediate volute and the pump adapter in two or three places around the pump to separate the castings Figure 5 Do not mar the sealing surfaces do not break pieces out of the adapt...

Page 2: ...olute align ing it with the mark made before disassembly Use the long cap screws to check this alignment It cannot be stressed too strongly that all bolt holes and water passages of all gaskets and vo...

Page 3: ...19 Base Volute 1 20 3 8 16 x 4 1 4 Capscrews 2 21 1 4 NPT Square Head Pipe Plug 1 20 100 80 60 40 9 10 1 3 4 5 6 7 8 2 11 21 19 18 14 14 16 16 17 13 15 20 1281 0705 12 12 Standard hardware item availa...

Page 4: ...ff rents autour de la pompe enfoncer PRUDEMMENT l aide d un marteau un petit tournevis ou un burin lame mince entre la volute interm diaire et l adaptateur de la pompe de fa on s parer les pi ces coul...

Page 5: ...nement On n insistera jamais trop sur le fait que tous les trous des boulons et des canalisa tions d eau de tous les joints et des volutes DOIVENT s aligner sinon la pompe n aura pas t remont e correc...

Page 6: ...illador peque o o con un cincel de hoja fina entre la voluta intermedia y el adaptador de la bomba en dos o tres lugares alrededor de la bomba para separar las piezas fundidas Figura 5 No estropee las...

Page 7: ...para chequear esta alineaci n Es importante recalcar que los orificios de los pernos y los pasajes de agua de todas las empa quetaduras y volutas DEBEN quedar alineados entre s o la bomba no estar de...

Page 8: ...J24 11 12 Roue 2 J105 76P 14 Joint 2 J20 11 J20 11 16 Bague d usure 2 J23 10 17 Bague d usure 1 J23 11 Contenu de la trousse Piezas no incluidas en el paquete Clave No Descripci n de la pieza Cantida...