CD7220/CD3220 CUSTOMER DISPLAY
20
CLR
/Clear display screen, and clear string mode/
ASCII Format
CLR
Dec. Format
[012]
Hex. Format
[0Ch]
Description
All the display characters will be cleared, and the string mode will be cancelled.
CAN
/Clear current line, and cancel string mode/
ASCII Format
CAN
Dec. Format
[024]
Hex. Format
[18h]
Description
The current line is cleared, and the string mode is cancelled.
ESC * n
/Brightness adjustment /
ASCII Format
ESC * n
Dec. Format
[027][042] n {3<=n<=4}
Hex. Format
[1Bh][2Ah][n]
Description
Adjust the brightness of the vacuum fluorescent display.
When n = 3 ,brightness = 70 %
When n = 4 ,brightness =100 %
ESC _ n
/Set cursor ON or OFF /
ASCII Format
ESC _ n
Dec. Format
[027][095] n {0<=n<=1}
Hex. Format
[1Bh][5Fh][n]
Description: Set cursor ON or OFF
When n = 0, cursor is OFF
When n = 1, cursor is ON
ESC f n
/Select international font/
ASCII Format
ESC f n
Dec. Format
[027][102] n
Hex. Format
[1Bh][66h][n]
Description
Set international font
n
International font set
n
International font set
A
G
I
J
U
F
S
U.S.A.
GERMANY
ITALY
JAPAN
U.K.
FRANCE
SPAIN
N
W
D
E
L
R
NORWAY
SWEDEN
DENMARK I
DENMARK II
SLAVONIC
RUSSIA
reserved
Table 6-11
ESC c n
/Select fonts /
ASCII Format
ESC c n
Dec. Format
[027][099] n
Hex. Format
[1Bh][63h][n]
Description
Select fonts
n
International font set
n
International
A
J
compliance with ASCII code
compliance with JIS code
R
L
compliance with RUSSIA code
compliance with SLAVONIC code
Table 6-12