background image

 

 

Installation Instructions 
 
 
 
 

 

CAUTION: This appliance must only be installed and used in rooms with permanent 
ventilation to local standards. 

          

Installation of the appliance and its connection to the electrical mains must only be carried out by 
QUALIFIED PERSONNEL. 
 
Before any procedure, it is important to check that the appliance is disconnected from the power 
supply. The manufacturer declines all responsibility for any damage arising from installation in breach 
of the regulations in force or from failure to comply with accident prevention regulations. 

 

Installation premises 

For the proper operation of this gas appliance, the air necessary for the 
combustion of the gas must be able to flow into the room naturally. The air 
must flow into the room directly through openings in the outside walls. 
These openings must have an unobstructed cross-section not less than 
2m

3

/h for each kW of power (see total power in kW on the appliance 

nameplate). 
 
This opening must be constructed so that it will not be obstructed from the 
inside or outside; and placed close to the floor, preferably on the side 
opposite to that on which the flue gases are discharged. If it is not feasible 
to provide these openings in the room where the appliance is installed, the 
necessary air may be taken from an adjacent room, provided that: 
·this room is not a bedroom or a hazardous environment, 
·this room is not in a vacuum, 
·the ventilation between the room where the appliance is installed and the 

adjacent room is guaranteed by permanent openings. 

 
Note that the minimum height from the hob to the kitchen cabinet is 

850mm. 

 

 

Dear Installer: 

 
Please  affix  data  label  provided  on  the  adjacent  cupboard 
near the appliance for future reference. Thank you. 

 

Summary of Contents for HO-1

Page 1: ...1 HO 2 HO 6 HO 7 As part of Parmco Appliances commitment to improving and updating product ranges we reserve the right to alter change and update technical specifications and appearance attributes of...

Page 2: ...by spills when cooking Any breakage or damage of glass items Any damage caused by non recommended product used for cleaning maintaining lubricating or similar Any aspect relating to the installation...

Page 3: ...e take special note of all detailed technical information and installation instructions It is essential that you follow these instructions to ensure the safety and reliability of this appliance Furthe...

Page 4: ...tchen units 13 Installation options 14 Guide to reading the instructions The following symbols will help you When reading the instructions Safety information Step by step instructions Suggestions and...

Page 5: ...herwise contact your dealer before putting the appliance into operation The Manufacturer declines all responsibility in the case of failure to comply with accident prevention regulations Make sure tha...

Page 6: ...nt Servicing work on this appliance must be carried out by a qualified technician only Always request the use of original spare parts Environmental protection advice All the materials used are environ...

Page 7: ...Symbol present on versions with lighting integrated in the control knob Dual triple flame version no gas flow maximum gas flow from central burner minimum gas flow from central burner maximum gas flow...

Page 8: ...attempts check that the burner cap and flame cap are correctly positioned To turn off the flame turn the control knob clockwise to the symbol Before removing pans from the burners always lower or turn...

Page 9: ...er and a little liquid detergent Do not use the following products household detergents or bleaches soaped scouring pads not suitable for non stick utensils steel wool scouring pads stain removers for...

Page 10: ...necessary repairs or adjustments must be carried out with the greatest care and attention For this reason we strongly advise you always to contact the Dealer who sold you the appliance or Parmco Serv...

Page 11: ...0 98 HO 1 6S 3GW 1 x 0 50 2 x 0 65 0 1 x 0 98 HO 2 75S 4GW 1 x 0 50 2 x 0 65 1 x 0 85 1 x 0 98 HO 2 6S 4G 1 x 0 50 2 x 0 65 1 x 0 85 0 HO 2 9S 4GW 1 x 0 50 2 x 0 65 1 x 0 85 1 x 0 98 HO 7 6G 3GW 1 x...

Page 12: ...through openings in the outside walls These openings must have an unobstructed cross section not less than 2m3 h for each kW of power see total power in kW on the appliance nameplate This opening mus...

Page 13: ...shown on the plate Otherwise follow the instructions provided in the Adapting to di erent types of gas section For maximum e ciency and minimum consumption make sure that the gas supply pressure comp...

Page 14: ...ppliance and the mains with at least 3mm between the contacts of suitable rating for the load while complying with the regulations in force The switch must not break contact in the yellow green earth...

Page 15: ...he supply pipeline Setting the minimum level 1 Light the burner as already described 2 Turn the tap to the minimum flame position 3 Remove the control knobs 4 LPG to NG Use a thin blade screwdriver to...

Page 16: ...n opening place the special gasket around the bottom edge of the hob It is important to fix this gasket evenly without gaps or overlapping in order to prevent liquid from seeping underneath the hob 1...

Page 17: ...rical connections of the hob and oven must be made separately both for electrical reasons and for simplifying the removal of the oven through the front of the cabinet The distance must be at least 750...

Reviews: