background image

 

 

14 

Installation options 

On base cabinet with door  

When construc

ti

ng the cabinet, suitable precau

ti

ons must be taken to prevent 

contact with the casing of the hob, which becomes very hot during opera

ti

on. 

The recommended method for overcoming this problem is illustrated on the 
right. 
 
The panel underneath the hob must be easily removable to allow the hob to be 
locked in posi

ti

on and released in case of servicing work. 

 

On base cabinet with oven  

Two possible methods for avoiding overhea

ti

ng are illustrated on the right. 

 
The electrical connec

tion

s of the hob and oven must 

be made separately both for electrical reasons and for 
simplifying the removal of the oven through the front 
of the cabinet. 
 
The distance must be at least 750mm between the gas 
hob and the ven

til

a

ti

on system, and must be at least 

850mm between the gas hob and the kitchen cabinet. 
 

 
 
 

 

Cutout Dimensions

                            

 

 

 

Model 

Dimensions (w x h) mm 

HO-1-2S-2G 

285x485 

HO-1-6S-3GW 

555x475 

HO-1-6W-3GW 

555x475 

HO-2-6S-4G 

560x495 

HO-2-75S-4GW 

735x495 

HO-2-9S-4GW 

735x495 

 HO-6-6S-3GW 

560x495 

HO-6-77S-4GW 

735x495 

HO-6-9S-4GW 

735x495 

HO-7-6G-3GW 

565x495 

HO-7-9G-4GW 

735x495 

When installing a rangehood above a gas appliance, all relevant New Zealand building, 

installation and regulation standards must be adhered to. 

 

Summary of Contents for HO-1

Page 1: ...1 HO 2 HO 6 HO 7 As part of Parmco Appliances commitment to improving and updating product ranges we reserve the right to alter change and update technical specifications and appearance attributes of...

Page 2: ...by spills when cooking Any breakage or damage of glass items Any damage caused by non recommended product used for cleaning maintaining lubricating or similar Any aspect relating to the installation...

Page 3: ...e take special note of all detailed technical information and installation instructions It is essential that you follow these instructions to ensure the safety and reliability of this appliance Furthe...

Page 4: ...tchen units 13 Installation options 14 Guide to reading the instructions The following symbols will help you When reading the instructions Safety information Step by step instructions Suggestions and...

Page 5: ...herwise contact your dealer before putting the appliance into operation The Manufacturer declines all responsibility in the case of failure to comply with accident prevention regulations Make sure tha...

Page 6: ...nt Servicing work on this appliance must be carried out by a qualified technician only Always request the use of original spare parts Environmental protection advice All the materials used are environ...

Page 7: ...Symbol present on versions with lighting integrated in the control knob Dual triple flame version no gas flow maximum gas flow from central burner minimum gas flow from central burner maximum gas flow...

Page 8: ...attempts check that the burner cap and flame cap are correctly positioned To turn off the flame turn the control knob clockwise to the symbol Before removing pans from the burners always lower or turn...

Page 9: ...er and a little liquid detergent Do not use the following products household detergents or bleaches soaped scouring pads not suitable for non stick utensils steel wool scouring pads stain removers for...

Page 10: ...necessary repairs or adjustments must be carried out with the greatest care and attention For this reason we strongly advise you always to contact the Dealer who sold you the appliance or Parmco Serv...

Page 11: ...0 98 HO 1 6S 3GW 1 x 0 50 2 x 0 65 0 1 x 0 98 HO 2 75S 4GW 1 x 0 50 2 x 0 65 1 x 0 85 1 x 0 98 HO 2 6S 4G 1 x 0 50 2 x 0 65 1 x 0 85 0 HO 2 9S 4GW 1 x 0 50 2 x 0 65 1 x 0 85 1 x 0 98 HO 7 6G 3GW 1 x...

Page 12: ...through openings in the outside walls These openings must have an unobstructed cross section not less than 2m3 h for each kW of power see total power in kW on the appliance nameplate This opening mus...

Page 13: ...shown on the plate Otherwise follow the instructions provided in the Adapting to di erent types of gas section For maximum e ciency and minimum consumption make sure that the gas supply pressure comp...

Page 14: ...ppliance and the mains with at least 3mm between the contacts of suitable rating for the load while complying with the regulations in force The switch must not break contact in the yellow green earth...

Page 15: ...he supply pipeline Setting the minimum level 1 Light the burner as already described 2 Turn the tap to the minimum flame position 3 Remove the control knobs 4 LPG to NG Use a thin blade screwdriver to...

Page 16: ...n opening place the special gasket around the bottom edge of the hob It is important to fix this gasket evenly without gaps or overlapping in order to prevent liquid from seeping underneath the hob 1...

Page 17: ...rical connections of the hob and oven must be made separately both for electrical reasons and for simplifying the removal of the oven through the front of the cabinet The distance must be at least 750...