5
3.1 Electrical connection
Make sure that the voltage and the cross-section of the power supply line match the specifications
indicated on the identification plate positioned on the back panel. Do not remove this plate for any reason.
If the appliance is connected to the power supply network by a fixed connection, install a multipolar cut-out
device on the power supply line with a contact opening distance equal to or greater then 3mm near the
appliance and in an easily reachable position.
Connection to the power supply network may be fixed or using a plug and socket. With the latter option,
the plug and socket must be suitable for the cable and conform with the regulations in force. Regardless of
the type of connection, it is compulsory that the appliance is earthed. Before connection, make sure that
the power supply line is suitably earthed. Avoid the use of adapters and shunts.
For operation on 220-240V: use a three-pole cable of H05RR-F or H05V2V2-F type:
3 x 1.0mm
2
for 60cm models
WARNING: The values indicated above refer to the cross section of the internal conductor.
3.2 Room Ventilation
The room containing the appliance should have an air supply in accordance with the standards in force. The
room where the appliance is installed must have enough air flow as required for the regular combustion of
gas and by the necessary air exchange of the same room. The air vent, protected by grills, must be suitably
dimensioned in compliance with the current regulations and positioned so that no part of it is obstructed.
The cooker must be kept adequately ventilated in order to eliminate the heat and humidity produced by
cooking. After prolonged use, it is recommended to open a window or to increase the speed of any
ventilators.
3.3 Extraction of the products of combustion
Extraction of the products of combustion must be ensured by means of hoods connected to a natural
draught chimney whose efficiency is assured or by forced extraction. An efficient extraction system
requires precision planning by a specialist qualified in this area and must comply with the positions and
distances indicated by the regulations.