24
It is possible to install the FS 600-CER and AR 900-CER units on a “plinth” if required. Special
ventilation is required in this application. Please refer to the diagram below.
•
The appliance should be placed on a plinth constructed of material suitable to carry the full
weight of the appliance.
•
The base of the plinth should be constructed of a suitable non-combustible material.
•
A 40mm air gap must be provided at the rear of the plinth.
•
6 air gaps of 100mm wide x 10mm high must be provided in the front face of the plinth.
If this appliance is placed on a base, measures must be taken to prevent the appliance from
slipping from the base.
Anti-Tilt/Hose Restraint Chain
Each appliance is supplied with a restraint chain. The restraint chain prevents strain being applied
to the hose when the appliance is pulled forward and prevents the appliance from tilting forward.
The chain should restrict the appliance movement to no more than 80% of the hose length.The
chain should be connected to a suitable anchor point as close to the behind of the appliance as
possible. If the appliance is installed between two cabinets, drill holes into the cabinetry and
secure the chains inside the cupboards.
WARNING: Ensure the chains are correctly anchored to prevent the appliance from tilting
forward and to prevent strain on the hose when the appliance is pulled forward.
MAKE SURE THE ANTI-TILTING CHAINS ARE TAUT WHEN ANCHORED TO PREVENT THE
APPLIANCE FROM TILTING.
Summary of Contents for FS 600-CER