10
5.2 Adjusting the minimum setting for hob burners (LPG)
In order to adjust the minimum with liquid gas, the screw on the side of the tap rod must be fully tightened
clockwise all the way. The bypass diameters for each individual burner are shown in section 4.2 Burner and
nozzle characteristics table. When the adjustment is completed, restore the sealing of the bypasses with
paint or other material.
5.3 Adjusting the minimum setting for the oven burner
Light the burner and turn it to the minimum position.
Remove the gas tap knob and turn the adjustment
screw on the side of the tap rod until the correct
minimum flame is achieved. Refit the knob and make
sure that the burner flame is stable, so that turning the
knob rapidly from the maximum to the minimum
position will not cause the flame to go out. Repeat the
operation on all the gas taps.
6. CONTROL PANEL
All the cooker controls are on the front panel.
AR 900-GAS GAS
AR 600-GAS GAS