22
© 2014 - 2024 Parktron Technology Ltd.
2.3.2. Wiring contacts for software programmable functions:
Signal outputs: (Refer to the drawing in section 2.2.1 for CN2/CN3/CN4 location)
CN
number
Connector-Contact
Name
Function description
CN2
CN2-L.C-COM
CN2-L.C-NC
CN2-L.C-NO
One sets of signal output contacts (Rating: 1A 220V 0r 2A
110V).
Providing a present signal output when lane closed for
system maintaining. Signal stop until lane opened again.
Normally utilized by drive way traffic light control.
L.C-COM : Common contact point for NC and NO
L.C-NC : Relay normal close.
L.C-NO : Relay normal open.
CN3
CN3-FULL
Providing a present signal output when parking full.
Signal stop when parking space available again.
CN3
CN3-O-2-A3
DB25-3/16
Providing a present signal output after ticket taken or
season card validated. Normally utilized to inhibit other
ticketing system (traffic smart card) on the terminal.
CN3
CN3-Counter1
CN3-Counter2
Providing a 0.2 second pulse signal output after barrier
gate arm closed. Normally utilized by parking space
counting system, exit warning light …etc.
CN4
O-LOOP2
Output signal from loop detector 2.
CN4
O-LOOP1
Output signal from loop detector 1.
CN4
O-2-A7
Spare Output
CN4
O-2-A6
Spare Output