© 2014 - 2024 Parktron Technology Ltd.
© 2014 - 2024 Parktron Technology Ltd.
14
15
(A)
220V
(
110V
)
power connection
:
Remove wiring terminal cover and connect power wire to [Power input
interface board]
.
(B)
Traffic light
(
R&G light
)
connection
:
The traffic light connector provides 220v power
.
Connect the Red
Light Wire, Green Light Wire and COM wires to the [R&G light output
interface board] according to text indication printed on the board
.
(C)
Photocell emitter and receiver connection
:
To use photocell device
,
first connect photocell (emitter and receiver)
to wiring terminal power output [Photocell power output]
,
and then
connect receiver signal wire to signal input [Photocell signal input] on
wiring terminal board.
(D)
Loop detector terminal
:
This controller can support both the internal and the external loop
detector connections
.
However
,
just one way can be chosen
.
If external loop detector is selected
,
just connect the loop detector
to 220V power
,
and connect the signal wire to the signal input
terminal
.
If the internal loop detector is selected
,
connect the internal loop
detector to the socket on the circuit board directly and the signal
wire to vehicles detector signal input terminal
.
(E)
"
COM
","
UP
","
DOWN
","
STOP
"
signal input terminal
:
The input terminal can work as a switch
.
If choose the
"
UP
",
"
DOWN
","
STOP
"
input terminal to connect to the
"
COM
"
by a
wire
,
the main board will give the correlative reaction signal to the
barrier gate arm
.
The user can use this method for the IC system controlling or the
circuitry controlling
.(
Note
:
the wire control is advised to be used
in the guards
'
room
)
(F)
"
UP
"
and
"
DOWN
"
position limit switch
:
This switch transmits the
"
UP
"
and
"
DOWN
"
command to boom by
optical signal
.(
Notice
:
More details please refer to Fig
.
12
)
(G)
RS485 serial communication terminal
:
The main board supports the Rs485 serial communication to control
the boom UP and DOWN
.
Please link the computer with Rs485
interface by the communication module
.
The software please refer to the instruction in the disk
.(
Optional
device
)
(H)
Terminal special for motorcade
:
If the users have installed the loop detector
,
and do not want the
barrier boom fall down automatically when there are still some cars
in line behind the passing car
.
Then please add an exterior circuit
to this device
.
If the circuit is on
,
the loop detector will work
;
if
the circuit is off
,
the loop detector will not work
.
Electric part adjustment and attentions
(A)
Barrier gate controlling
:
There are three buttons to control the barrier gate conveniently
when the barrier gate sets well
.
If the boom can not fall down or rise up to the right position
,
or
rises up automatically after reaching the horizontal position
,
please
check whether the abnormal situation is caused by loop detector
or not
.
If the abnormal situation mentioned above is not caused by loop
detector
,
please check the
"
Gate Type Selection
"
setting
.
(
Note
:
the barrier gate speed has been fixed
.
And this
"
Gate Type
Selection
"
is just for controller adjustment to keep its
'
working
speed accord with the barrier gate speed
.)
The
"
Gate Type
Selection has been well set before leaving our factory
,
but user
can adjust
it if needed
.
(B)
Boom backtrack function
:
The boom will rise up if it comes across obstacles when falling
.
And it will stop if it hits something when rising
.
(C)
Infrared photocell function
:
If the infrared signal is cut off when the boom is falling
,
the boom
will rise up automatically
.
(D)
R&G light terminal
:
The light will turn green only when the boom is at the vertical
position
.
Red light is for other positions
.
(E)
Loop detector terminal
:
If the vehicles detector is installed correctly
,
the boom will
automatically rise up when there is some press of the vehicle on the
loop
,
and it will automatically fall after the vehicles leaves the loop
.