1 8
GB
Troubleshooting
Always unplug the shredder before working on it.
Risk of electric shock!
Problems
Possible Cause
Error correction
Device doesn‘t start
Mains voltage missing
Main circuit breaker is tripped
Check the socket, mains cable,
line, mains plug, repairs to be
carried out by qualified electri
-
cian if necessary, check main
circuit breaker.
On/off switch (
5) may be
defective
Repair by Customer Care
Engine faulty
Grinding tool does
not move although
the engine is run-
ning
Grinding disc nut is loose
Tighten grinding disc nut (see
„Changing disc“)
Workpiece, remaining workpie-
ces or remaining grinding tools
block drive
Remove blockages
Engine is slower
and stops
Device is overloaded through
workpiece
Reduce pressure on grinding tool
Workpiece unsuitable
Grinding disc does
not rotate smoothly,
abnormal noises
can be heard
Grinding disc nut is loose
Tighten grinding disc nut (see
„Changing disc“)
Grinding disc is defective
Change grinding disc
Waste disposal
and environmental
protection
Be environmentally friendly. Return the tool,
accessories and packaging to a recycling
centre when you have finished with them.
Electrical machines do not belong
with domestic waste.
• Hand over the device at an utilization
location. The plastic and metal parts
employed can be separated out and
thus recycled use can be implemented.
Ask our Service-Center for details.
• Defective units returned to us will be dis-
posed of for free.
Summary of Contents for PWS 125 D3
Page 3: ...1 2 3 4 8 9 7 5 6 11 12 13 14 19 18 17 22 21 20 15 16 25 24 23 10 ...
Page 62: ...6 2 S I ...
Page 126: ...126 ...
Page 128: ...128 ...