1 5
GB
4. Take off the locknut (
16) and
the adapter flange (
15) from
the spindle flange (
17).
5. Open the tightening lever ( 19).
6. Place the protective hood
(
14) on the positioning holes.
7. Turn the protective hood (
14)
into the working position. The
closed side of the protective hood
must always face the operator.
8. Close the tightening lever
(
19) again. The protective
hood should not be able to be
turned any more.
9. Install the locknut (
16) and
adapter flange (
15) in rever-
se order.
10. Readjust the position of the pro-
tective hood if you find during
use that it does not provide opti-
mum protection.
If needed, the tension on the adjustment
nut (
1
8) can be set. Use the chuck key
(
13) for this.
Installing/changing disc
1. Press the spindle stop button
(
9).
2. Turn the mounting spindle (
17) until the spindle lock fixed
the mounting spindle. Keep and
continue to hold down the spind-
le lock button (
9)
3. Release the clamping nut
(
16) with the chuck key
(
13). You can release the
spindle lock button (
9).
4. Set the desired disc onto the
mounting flange (
15). label
on the disc should always face
the device.
5. Set the clamping nut (
16)
on the mounting spindel (
17) again. The flat side of the
clamping nut must face the at-
tachment tool.
6. Press the spindle stop button
(
9) and turn the mounting
spindle (
17), until the spindle
toggle button holds the spindle
flange in a fixed position. Pull the
clamping nut (
16) tight again
using the chuck key (
13).
You can let go of the spindle lock
button (
9).
Operation
Caution! Risk of injury!
- Always remove the mains plug
before working on the tool.
- Only use grinding discs and acces-
sories recommended by the ma-
nufacturer. Using other attachment
tools and other accessories can
represent a risk of injury for you.
- Only use grinding tools which
bear information about the
manufacturer, type of binding,
dimension and permitted number
of revolutions.
- Only use grinding discs where
the printed rotational speed is at
least as high as what has been
specified on the name plate of
the device.
- Do not use any broken, cracked,
or
otherwise damaged grinding
discs.
- Never operate the device wit-
hout protective equipment.
- Support the plates or workpieces
in order to reduce the risk of
kickback from a jammed cutting
disc.
Large workpieces may
Summary of Contents for PWS 125 D3