PTS 20-Li A1
GB
│
IE
│
23
■
Technical specifications
Rated voltage
20 V
(DC)
Idle speed
n/ n
0
4500 rpm
Max. cutting depth:
25 mm
max.25
mm
Thread size
M6
Battery: PAP 20 A1
Type
LITHIUM
ION
Rated voltage
20 V
(DC)
Capacity
2 Ah/40 Wh
Cells 5
High-speed battery charger PLG 20 A1
INPUT
Rated voltage
230–240 V ∼, 50 Hz
(AC)
Rated power
consumption
65
W
Fuse (internal)
3.15 A
OUTPUT
Rated voltage
21.5 V
(DC)
Rated current
2.4 A
Charging time
approx. 60 min.
Protection class
II / (double insulation)
Noise and vibration data
Noise measurement value determined in
accordance with EN 62841. The A-rated
noise level of the power tool is typically:
Sound pressure level
L
pA
= 81.7 dB (A)
Uncertainty K
PA
= 3 dB
Sound power level:
L
WA
= 92.7 dB (A)
Uncertainty K
WA
= 3 dB
Wear ear muffs!
Total vibration value
Sawing wood
a
h,W
= 1.819 m/s
2
Uncertainty K
=
1.5
m/s
2
Sawing ceramics
a
h
= 3.5 m/s
2
Uncertainty K
=
1.5
m/s
2
NOTE
►
The vibration emission values and the noise
emission values given in these instructions
have been measured in accordance with a
standardised test procedure and can be used
for comparing one power tool with another.
►
The specified total vibration values and the
noise emission values can also be used to
make a provisional load estimate.
WARNING!
►
Depending on the manner in which the power
tool is being used, and in particular the kind
of workpiece being worked, the vibration and
noise emission values can deviate from the
values given in these instructions during actual
use of the power tool.
►
Try to keep the vibration load as low as
possible. Measures to reduce the vibration
load are, e.g. wearing gloves and limiting the
working time. Wherein all states of operation
must be included (e.g. times when the power
tool is switched off and times where the
power tool is switched on but running without
load).
General Power
Tool Safety Warnings
WARNING!
►
Read all safety warnings, instructions,
illustrations and specifications provided
with this power tool.
Failure to follow all
instructions listed below may result in electric
shock, fire and/or serious injury.
IB_308629_PTS20-LiA1_LB8.indb 23
13.03.2020 08:37:04