PDWE 8 B2
GB
│
MT
│
37
■
Oil mister unit
The oil mister unit is connected to the filter unit .
Its function is to lubricate the filtered compressed air
which is being transported in the direction of the
compressed air tool .
The fill level of the oil reservoir (integrated in the
oil mister unit) can be inspected through the trans-
parent viewing window . Use only oil that is suitable
for this compressed air maintenance unit (see
above) .
♦
Turn the oil outlet screw (mounted on the
sight glass) clockwise ("–") to reduce the
amount of oil required . Turn it anticlockwise
("+") to increase the amount of oil .
♦
The integrated sight glass makes continuous
monitoring of the filtered compressed air
possible .
♦
To top up the oil, unscrew the screw of the oil
refill inlet with a suitable Allen key . Fill the
container with the help of a suitable funnel and
then replace the screw using the Allen key .
Fault
Causes
The solution
Insufficient
lubrication .
Oil outlet screw
turned too far
in direction ("–") .
Increase the oil
quantity
The compressed
air oil quantity is
too low, i .e .
below the
minimum fill
quantity .
Pour more oil
into the oil
reservoir .
Pay attention to
the maximum
filling quantity .
The oper-
ating pres-
sure of the
compressed
air is too
weak .
The pressure
regulator is
closed too
tightly .
Increase the
pressure .
Maintenance and cleaning
WARNING! RISK OF INJURY!
Disconnect the appliance from
the compressed air supply.
NOTE
►
The compressed air maintenance unit must be
serviced and overhauled at regular intervals
to ensure proper functioning and compliance
with safety requirements . Improper and incor-
rect operation can lead to failures and
damage to the appliance .
■
Never use harsh and/or abrasive cleaning
agents or solvents . These could damage the
plastic parts of the compressed air mainte-
nance unit .
■
Never allow water to get inside the oiler .
■
Make sure that the housing and the inside of
the compressed air maintenance unit remain
free of dust and dirt . To ensure this is the case,
wipe the compressed air maintenance unit
regularly with a clean cloth .
■
Clean the compressed air maintenance unit and
the connections at regular intervals with a damp
cloth .
■
Empty the tank of the compressed air mainte-
nance unit at regular intervals . To do this, press
the drain valve (see fig . G) on the underside
upwards . Please note that the compressed air
maintenance unit must be pressure-free for
safety reasons .
Disconnect the compressed air maintenance
unit from the compressed air source .
The drain valve opens as soon as it is discon-
nected from the compressed air .