PDAP 75 A1
GB
│
MT
│
57
■
Noise emission values:
Noise measurement determined in accordance with ISO 15744:
Sound pressure level:
L
pA
=
84 .1 dB(A)
Uncertainty: K
pA
=
3 dB
Sound power level:
L
WA
=
95 .1 dB(A)
Uncertainty:
K
WA
=
3 dB
Wear ear protection!
Vibration emission value:
Vibration values determined in accordance with ISO 28927-3 and
EN 12096:
a
h
= 0 .25 m/s
2
Uncertainty K = 0 .52 m/s
2
WARNING!
►
The noise emission levels specified in these instructions have
been measured in accordance with the standardised measur-
ing procedure specified in ISO 15744 and can be used to
make equipment comparisons . The noise emission values vary
in accordance with the use of the compressed air tool and may
be higher than the values specified in these instructions in some
cases . It is easy to underestimate the noise emission load if the
compressed air tool is used regularly in a certain manner .
NOTE
►
For an accurate estimate of the noise emission load during a
certain working period, the times during which the appliance is
switched off or is running but not actually being used must also
be taken into consideration . This can significantly reduce the
noise emission load over the total working period .
Summary of Contents for PDAP 75 A1
Page 3: ......
Page 105: ...PDAP 75 A1 102 DE AT CH...