JINCHW09 Rev A 12/05/14
Rope
-
Check the rope around the door. If rope is
becoming detached, use Parkray Ltd rope glue to
reattach it. If the rope is in a poor condition, a
replacement rope kit may be ordered from the
Parkray Ltd spares range.
Chimney & Flueways
-
It is important that the
chimney, flueways and any connecting flue pipe
are swept regularly. This means at least once a
year for smokeless fuels and at least twice a year
for wood and other fuels.
The baffle will need to be removed from its
supports in order to sweep the chimney (see
‘Removing internal components’ instructions).
Only wire-centred sweeps’ brushes fitted with a
guide wheel should be used.
If it is not possible to sweep all parts of the
chimney through the appliance, ensure there is
adequate access to cleaning doors.
Seasonal use
-
If the appliance has been unused
for a long period of time, such as during the spring
and summer months, the chimney should be
checked for potential obstructions by a competent
person before lighting the stove.
Gaskets
-
all gaskets used on this appliance are
produced from a heat resistant material called
Manniglas. The glass gasket will have to be
replaced when a new piece of glass is fitted as the
gaskets become brittle after firing the stove. Over
time you may find that the gasket changes colour.
This is due to a reduction in the pigment used in
the manufacture of the product and no cause for
concern.
De-ashing –
De-ashing should be carried out on a
regular basis to avoid a build up of ash and ensure
sufficient primary air flow. Empty the ashpan
regularly to prevent ash reaching the underside of
the great bars.
When de-ashing ensure the
primary air channel at the front left of the stove is
clear of ash. If necessary this can be periodically
cleared with a vacuum cleaner. The primary air
cover can be removed by undoing the two screws
if required.
Trouble Shooting
F
IRE
W
ILL
N
OT
B
URN
Check that –
Chimneys and flueway are clear.
A suitable fuel is being used.
There is an adequate air supply into the room.
An extractor fan is not fitted in the same
room.
Flue draught is above minimum level (see
installation instructions).
F
IRE
B
LAZING
O
UT OF
C
ONTROL
Check that –
The door is tightly closed.
The air controls are in the closed position.
A suitable fuel is being used.
The glass is not loose.
The door rope seal is in good condition.
Flue draught is below maximum level (see
installation instructions).