JINCNS05 RevF 27/04/12 
 

 

Minimum Draught – 1.2mm Water Gauge 

Maximum Draught – 2.5mm Water Gauge 

Air Supply 

The  room  or  space  containing  this  appliance 

should  have  purpose  provided  ventilation 

(where  necessary)  in  accordance  with  Building 

Regulations. 

 

Due  consideration  should  be  given  to  air 

requirements  for  any  other  appliance  in  the 

same room or space. 

 

Any  air  opening  must  be  kept  clear  from 

blockage or obstruction. 

Hearth/ Material Clearances  

Your  stove  must  be  installed  on  a  floor  with 

adequate  load-bearing  capacity,  otherwise 

suitable measures should be taken.  

Use the adjusting screws in the feet to level the 

stove. 

The  stove  can  be  recessed  into  a  suitably  sized 

fireplace.  Ensure  there  is  a  free  air  gap  of  at 

least 150mm above and 50mm around the sides 

and rear of the stove.  

Where  possible  it  is  recommended  that  a  free 

air  gap  of  150mm  or  more  is  left  around  the 

sides  of  the  stove  to  obtain  maximum  heat 

output  and  to  gain  access  to  the  rear  of  the 

stove. 

The hearth should extend at least 225 mm from 

the front of the stove. 

 If the stove is to stand in an appliance recess, it 

should  stand  wholly  above  a  solid,  non-

combustible hearth, at least 125 mm thick (this 

may include the thickness of a solid floor).  

If  the  stove  is  not  to  stand  in  an  appliance 

recess,  it  may  stand  wholly  above  a  hearth 

made  of  non-combustible  board  /  sheet 

material or tiles, at least 12mm thick.  

 

The hearth should extend at least 150 mm from 

the sides and rear of the stove, and at least 225 

mm from the front of the stove.  

All non-combustible walls closer than 300mm to 

the stove should be at least 75mm thick. 

Minimum Distances to Combustible Material 

Behind the stove 

650mm 

At the side of the stove 

400mm 

In front of the stove 

900mm 

 

Note:  combustible  material  refers  to  any 

material  that  will  degrade  when  subjected  to 

heat e.g. plaster. 

No  combustible  material  must  be  stored 

underneath the stove. 

Summary of Contents for CONSORT SLIMLINE 5

Page 1: ...JINCNS05 RevF 27 04 12 CONSORT SLIMLINE 5 CleanBurn Stove Installation and Operating Instructions ...

Page 2: ...cation Appliance Mass 88 kg Total Efficiency 74 1 Nominal Heat Output 4 2 kW Mean CO Emission 13 O2 0 32 Mean Flue Gas Temperature 268 C Flue Gas Mass Flow 5 0 g s This appliance is not for use in shared flue This appliance is suitable for intermittent burning ...

Page 3: ...ding control body in advance of any work starting CO Alarms Building regulations require that whenever a new or replacement fixed solid fuel or wood biomass appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s ...

Page 4: ...for long periods without first adjusting the controls to a safe setting Careful air supply control should be exercised at all times Fume Emission WARNING NOTE Properly installed operated and maintained this appliance will not emit fumes into the dwelling Occasional fumes from de ashing and refuelling may occur However persistent fume emission is potentially dangerous and must not be tolerated If f...

Page 5: ...liance If the alarm sounds unexpectedly follow the instructions given under Warning Note in the Fume Emission section In the Event of a Chimney Fire Raise the alarm Call the Fire Brigade Close appliance air controls Move furniture ornaments etc away Place a fireguard in front of stove Check the chimney breast for signs of excessive heat Ensure the Fire Brigade can gain access to your roof space in...

Page 6: ...ixing holes Secure in place using the M6 nuts and washers Slide the remaining gasket on to the studs of the flue collar or blanking plate and secure in place on the back plate Unless the optional flue damper is being fitted blank off the damper handle holes in the flue collar using the two M8 coach bolts Fire Bricks The Fire Bricks in this appliance are factory fitted The following set of photos s...

Page 7: ...Brick Pull the top edge of the Rear Brick forward and lift the brick out of the Stove Baffle Throat Plate Lift the Baffle and slide to the left When the right side of the Baffle clears the Baffle Support lower the Baffle into the Fire Box and remove To assemble the stove simply reverse the above procedure ...

Page 8: ...tallation If you have any doubts about the suitability of your chimney consult your local dealer stockist Connection to the Chimney The chimney must be swept before connection to the stove An existing fireplace opening can be bricked up or sealed with a register plate A short length of flue pipe of minimum 125mm internal diameter may then be used to connect the stove to the chimney This flue pipe ...

Page 9: ...150mm or more is left around the sides of the stove to obtain maximum heat output and to gain access to the rear of the stove The hearth should extend at least 225 mm from the front of the stove If the stove is to stand in an appliance recess it should stand wholly above a solid non combustible hearth at least 125 mm thick this may include the thickness of a solid floor If the stove is not to stan...

Page 10: ... output for at least 24 hours On completion of the installation and commissioning ensure that the operating instructions and operating tools for the stove are left with the customer Advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and warn them to use only the recommended fuels for the stove Advise the user on what to do should smoke or fumes be...

Page 11: ...ed by moving the slider to the right On the double door versions the amount of air is increased by moving the sliders outwards This provides a conventional air draught to the bed of the fire Secondary Air Secondary air is controlled via the slider above the door it is this Airwash that keeps a clean and uninterrupted view of the fire The amount of air can be increased by moving the slider to the r...

Page 12: ...ew fuel charge will ignite quickly If there are too few embers add some kindling to prevent excessive smoke Lighting the Stove We recommend that you have two or three small fires before you operate your stove to its maximum heat output This is to allow the paint to cure in steadily and to give a long service life of the paint finish During this curing in process you may notice an unpleasant smell ...

Page 13: ...oke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in t...

Page 14: ...aint and this can be cleaned with a soft brush Do not clean whilst the stove is hot The finish can be renovated with Parkray Stoves paint Glass Panel Clean the glass panel when cool with Parkray Stoves glass cleaner Highly abrasive substances should be avoided as these can scratch the glass and make subsequent cleaning more difficult Wet logs on heated glass a badly aimed poker or heavy slamming o...

Page 15: ... the air controls fully open If the appliance has been unused for a long period of time such as during the spring and summer months a competent person should check the chimney for potential obstructions before lighting the stove Gaskets All gasket used on this appliance are produced from a heat resistant material called Manniglas The glass gasket will have to be replaced when a new piece of glass ...

Page 16: ...s Single Door CH06 001 Door Handle CHC04 010 Door Slider CH08 003 Rope Sealing Kit SCPCN07SDSK Glass Clip Screw FSJM05008SS Glass Clip HHR08 046 Door Slider Knob HHR08 045 Door Catch Assembly DCCN07 Door Glass CH06 016 Door Cover CH06 002 Glass Gasket CH06 017 ...

Page 17: ...08 045 Door Glass CH06 018 Door Handle CHC04 010 Left Hand Door CH06 004 Door Handle CHC04 010 Door Slider CH05 033 Door Slider CH05 033 Glass Clip HHR08 046 Glass Clip Screw FSJM05008SS Glass Gasket CH06 019 Door Catch Assembly DCCN07 Glass Gasket CH06 019 Rope Sealing Kit SCPCN07NDSK Rope Sealing Kit SCPCN07NDSK Glass Clip HHR08 046 Glass Clip Screw FSJM05008SS ...

Page 18: ...HHW05 015 Rear Brick CNS05 006 Hinge CH08 064 Hinge Pin FRRM06025 Tertiary Air Bar HH06 101 Recouping Baffle HHW05 063 Side Brick CNS05 007 Riddling Support HH06 022 Riddling Bar Upper CNS06 002 Riddling Bar Lower CNS06 001 Operating Tool HFR07 040 Cam Bar HHR06 007 Catch Bar CNS07 004 ...

Reviews: