General Guidance 

It  is  important  that  your  stove  is  correctly 

installed  as  Parkray  Stoves  cannot  accept 

responsibility  for  any  fault  arising  through 

incorrect use or installation. 

 

These  instructions  cover  the  basic  principles  to 

ensure  satisfactory  installation  of  the  stove, 

although detail may need slight modification to 

suit particular local site conditions.  

 

The  installation  must  comply  with  current 

Building  Regulations,  national  and  European 

standards,  Local  Authority  byelaws  and  other 

specifications  or  regulations  as  they  affect  the 

installation of the stove.  

 

The Building Regulations requirements may also 

be 

met 

by 

adopting 

the 

relevant 

recommendations  in  the  current  issues  of 

British Standards BS 8303 and BS EN 15287-1. 

Competent Persons Scheme 

Parkray  Stoves  recommend  that  this  stove  is 

installed  by  a  member  of  an  accredited 

competent persons scheme e.g. HETAS. 

 

If the installer is not a member of a competent 

persons  scheme,  it  is  a  legal  requirement  to 

notify  your  local  building  control  body  in 

advance of any work starting. 

CO Alarms 

Building  regulations  require  that  whenever  a 

new  or  replacement  fixed  solid  fuel  or 

wood/biomass  appliance  is  installed  in  a 

dwelling,  a  carbon  monoxide  alarm  must  be 

fitted in the same room as the appliance. 

 

Further  guidance  on  the  installation  of  the 

carbon  monoxide  alarm  is  available  in  BS  EN 

50292:2002 and from the alarm manufacturer’s 

instructions. 

Provision of an alarm must not be considered a 

substitute  for  either  installing  the  appliance 

correctly  or  ensuring  regular  servicing  and 

maintenance  of  the  appliance  and  chimney 

system. 

Health and Safety Precautions 

Special  care  must  be  taken  when  installing  the 

stove such that the requirements of the Health 

and Safety at Work Act are met. 

Handling 

Adequate  facilities  must  be  available  for 

loading, unloading and site handling.  

Fire Cement 

Some  types  of  fire  cement  are  caustic  and 

should  not  be  allowed  to  come  into  contact 

with  the  skin.  In  case  of  contact,  wash 

immediately with plenty of water.  

Asbestos 

This  stove  contains  no  asbestos.  If  there  is  a 

possibility  of  disturbing  any  asbestos  in  the 

course of installation then please seek specialist 

guidance  and  use  appropriate  protective 

equipment.  

Summary of Contents for CONSORT SLIMLINE 5

Page 1: ...JINCNS05 RevF 27 04 12 CONSORT SLIMLINE 5 CleanBurn Stove Installation and Operating Instructions ...

Page 2: ...cation Appliance Mass 88 kg Total Efficiency 74 1 Nominal Heat Output 4 2 kW Mean CO Emission 13 O2 0 32 Mean Flue Gas Temperature 268 C Flue Gas Mass Flow 5 0 g s This appliance is not for use in shared flue This appliance is suitable for intermittent burning ...

Page 3: ...ding control body in advance of any work starting CO Alarms Building regulations require that whenever a new or replacement fixed solid fuel or wood biomass appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as the appliance Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s ...

Page 4: ...for long periods without first adjusting the controls to a safe setting Careful air supply control should be exercised at all times Fume Emission WARNING NOTE Properly installed operated and maintained this appliance will not emit fumes into the dwelling Occasional fumes from de ashing and refuelling may occur However persistent fume emission is potentially dangerous and must not be tolerated If f...

Page 5: ...liance If the alarm sounds unexpectedly follow the instructions given under Warning Note in the Fume Emission section In the Event of a Chimney Fire Raise the alarm Call the Fire Brigade Close appliance air controls Move furniture ornaments etc away Place a fireguard in front of stove Check the chimney breast for signs of excessive heat Ensure the Fire Brigade can gain access to your roof space in...

Page 6: ...ixing holes Secure in place using the M6 nuts and washers Slide the remaining gasket on to the studs of the flue collar or blanking plate and secure in place on the back plate Unless the optional flue damper is being fitted blank off the damper handle holes in the flue collar using the two M8 coach bolts Fire Bricks The Fire Bricks in this appliance are factory fitted The following set of photos s...

Page 7: ...Brick Pull the top edge of the Rear Brick forward and lift the brick out of the Stove Baffle Throat Plate Lift the Baffle and slide to the left When the right side of the Baffle clears the Baffle Support lower the Baffle into the Fire Box and remove To assemble the stove simply reverse the above procedure ...

Page 8: ...tallation If you have any doubts about the suitability of your chimney consult your local dealer stockist Connection to the Chimney The chimney must be swept before connection to the stove An existing fireplace opening can be bricked up or sealed with a register plate A short length of flue pipe of minimum 125mm internal diameter may then be used to connect the stove to the chimney This flue pipe ...

Page 9: ...150mm or more is left around the sides of the stove to obtain maximum heat output and to gain access to the rear of the stove The hearth should extend at least 225 mm from the front of the stove If the stove is to stand in an appliance recess it should stand wholly above a solid non combustible hearth at least 125 mm thick this may include the thickness of a solid floor If the stove is not to stan...

Page 10: ... output for at least 24 hours On completion of the installation and commissioning ensure that the operating instructions and operating tools for the stove are left with the customer Advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and warn them to use only the recommended fuels for the stove Advise the user on what to do should smoke or fumes be...

Page 11: ...ed by moving the slider to the right On the double door versions the amount of air is increased by moving the sliders outwards This provides a conventional air draught to the bed of the fire Secondary Air Secondary air is controlled via the slider above the door it is this Airwash that keeps a clean and uninterrupted view of the fire The amount of air can be increased by moving the slider to the r...

Page 12: ...ew fuel charge will ignite quickly If there are too few embers add some kindling to prevent excessive smoke Lighting the Stove We recommend that you have two or three small fires before you operate your stove to its maximum heat output This is to allow the paint to cure in steadily and to give a long service life of the paint finish During this curing in process you may notice an unpleasant smell ...

Page 13: ...oke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been authorised in Regulations and that appliances used to burn solid fuel in t...

Page 14: ...aint and this can be cleaned with a soft brush Do not clean whilst the stove is hot The finish can be renovated with Parkray Stoves paint Glass Panel Clean the glass panel when cool with Parkray Stoves glass cleaner Highly abrasive substances should be avoided as these can scratch the glass and make subsequent cleaning more difficult Wet logs on heated glass a badly aimed poker or heavy slamming o...

Page 15: ... the air controls fully open If the appliance has been unused for a long period of time such as during the spring and summer months a competent person should check the chimney for potential obstructions before lighting the stove Gaskets All gasket used on this appliance are produced from a heat resistant material called Manniglas The glass gasket will have to be replaced when a new piece of glass ...

Page 16: ...s Single Door CH06 001 Door Handle CHC04 010 Door Slider CH08 003 Rope Sealing Kit SCPCN07SDSK Glass Clip Screw FSJM05008SS Glass Clip HHR08 046 Door Slider Knob HHR08 045 Door Catch Assembly DCCN07 Door Glass CH06 016 Door Cover CH06 002 Glass Gasket CH06 017 ...

Page 17: ...08 045 Door Glass CH06 018 Door Handle CHC04 010 Left Hand Door CH06 004 Door Handle CHC04 010 Door Slider CH05 033 Door Slider CH05 033 Glass Clip HHR08 046 Glass Clip Screw FSJM05008SS Glass Gasket CH06 019 Door Catch Assembly DCCN07 Glass Gasket CH06 019 Rope Sealing Kit SCPCN07NDSK Rope Sealing Kit SCPCN07NDSK Glass Clip HHR08 046 Glass Clip Screw FSJM05008SS ...

Page 18: ...HHW05 015 Rear Brick CNS05 006 Hinge CH08 064 Hinge Pin FRRM06025 Tertiary Air Bar HH06 101 Recouping Baffle HHW05 063 Side Brick CNS05 007 Riddling Support HH06 022 Riddling Bar Upper CNS06 002 Riddling Bar Lower CNS06 001 Operating Tool HFR07 040 Cam Bar HHR06 007 Catch Bar CNS07 004 ...

Reviews: