background image

12 

 

Appliance Dimensions Aspect  

 

Dimensions Aspect 4 Compact/Aspect 4 
BOTH   

 

 

 

 

COMPACT 

 

 

 

STANDARD 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Dimensions Aspect 5 Compact/Aspect 5 
BOTH   

 

 

 

 

COMPACT 

 

 

 

STANDARD 

 
 
 
 
 
 
 
 
 
 
 
 

Dimensions Aspect 5 Slimline 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for ASPECT 14

Page 1: ...PACT ASPECT 5 5 COMPACT ASPECT 5 SLIMLINE ASPECT 6 ASPECT 7 ASPECT 8 SLIMLINE ASPECT 8 ASPECT 9 ASPECT 14 WOODBURING STOVE MODELS Instructions for Installation Operating Maintenance Servicing JINSPADA REV C 06 06 2019 ...

Page 2: ...2 STOVE MODELS ASPECT 4 ASPECT 4 COMPACT CVSPA04WS CVSPA04WB CVSPA04CWS CVSPA04CWB ASPECT 5 ASPECT 5 COMPACT CVSPA05WS CVSPA05WB CVSPA05CWS CVSPA05CWB ...

Page 3: ...IMLINE ASPECT 6 CVSPA05SWS CVSPA05SWB CVSPA06WS CVSPA06WB ASPECT 7 ASPECT 8 SLIMLINE CVSPA07WS CVSPA07WB CVSPA08SWS CVSPA08SWB ASPECT 8 ASPECT 9 CVSPA08WS CVSPA08WB CVSPA09WS CVSPA09WB ASPECT 14 CVSPA14WS CVSPA14WB ...

Page 4: ...0 OPERATING INSTRUCTIONS 20 23 MAINTENANCE SERVICING 23 25 TROUBLESHOOTING DATA PLATE 26 27 SPARES 28 34 COMMISSIONING INSTALLATION CHECK LIST 35 SERVICE RECORDS 36 FULL WARRANTY INFORMATION 37 38 Welcome to the Hunter Stoves family and thank you for purchasing a Parkray Aspect stove This stove was designed and built to be a high performance heating appliance and we hope it will bring you great en...

Page 5: ...25mm 125mm 125mm 125mm VENTILATION Where leakage is greater than 5m hour m Ventilation normally required 550mm per kW output over 5kW NONE NONE NONE NONE NONE NONE Where leakage is less than or equal to 5m hour m Ventilation normally required 550mm per kW output 2695 mm 2695 mm 2695 mm 2695 mm 2695 mm 2695 mm For further information on ventilation please refer to Building Regulations Document J or...

Page 6: ...L Aspect 7 Aspect 8 Slimline Aspect 8 Aspect 9 Aspect 14 Energy Efficiency Class A A A A A Nominal Heat Output Wood 4 9kW 4 9kW 6 0kW 8 0kW 9 5kW Energy Efficiency EEI 103 105 105 97 97 Efficiency Wood 78 1 79 2 79 2 73 6 71 9 Mean CO 13 O Wood 0 23 0 24 0 12 0 11 0 12 Appliance Mass 86kg 98kg 110kg 100kg 130kg Recommended Fuels Wood Seasoned Wood less than 20 moisture content Log Length 350mm 350...

Page 7: ...he discretion of a qualified installer and a flue draught interference test must be performed Do not obstruct the ventilation required for the safe use of this appliance Competent Persons Scheme Hunter Stoves Group recommend that this stove be installed by a member of an accredited competent persons scheme e g HETAS If the installer is not a member of a competent person s scheme it is a legal requ...

Page 8: ...This appliance should not be operated with the door open If fume emission persists then the following immediate action should be taken Open doors and windows to ventilate the room Let the fire go out or eject and safely dispose of fuel from the appliance Check for flue chimney blockage and clean if required Do not attempt to re light the fire until the cause of the fume emission has been identifie...

Page 9: ...as well as protect the internal components from damage during the installation process Fuel Retainer Bottom Grate Brick Side Bricks Open the door and remove the fuel retainer A Lift upwards B push inwards and then remove from the body Lift up baffle and pull the top of the brick inwards A and then remove from stove B Lift up bottom grate brick on one side A and slide out of stove B ...

Page 10: ...rop one edge downward into the bottom of the stove and pull outwards B Place the flue collar gaskets on the outlet to be used Push the upper brick upwards A Then pull the bottom edge of the rear brick forward B and lift the brick out of the stove Repeat with the lower brick Top and rear outlet ...

Page 11: ... by contacting your Local Authority To remove the secondary air stop remove the two screws and then take off the plate as per the diagram below Re Assembling The Stove Refit all the internal parts by following the removing internal component instructions in reverse order Wind the four M6 studs supplied into the fixing holes in the flue collar until finger tight Place the flue collar onto the stove...

Page 12: ...12 Appliance Dimensions Aspect Dimensions Aspect 4 Compact Aspect 4 BOTH COMPACT STANDARD Dimensions Aspect 5 Compact Aspect 5 BOTH COMPACT STANDARD Dimensions Aspect 5 Slimline ...

Page 13: ...13 Dimensions Aspect 6 Dimensions Aspect 7 Dimensions Aspect 8 Slimline ...

Page 14: ...14 Dimensions Aspect 8 Dimensions Aspect 9 Dimensions Aspect 14 ...

Page 15: ...the chimney flue system for cleaning and the removal of debris If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a twin walled insulated stainless steel flue to BS4543 can be used These chimneys must be fitted in accordance with the manufacturer s instructions and Building Regulations New masonry and flue block ...

Page 16: ...of the Health Safety code of practice and any other legislation that may have been introduced since the publication of these instructions Competent Persons Scheme Members of the following schemes may self certify the installation of this stove If the installer is not a member of one of these schemes your local Building Control Department must approve the installation Scheme Web address Telephone A...

Page 17: ... The optional rear and upper heat shields must be fitted to achieve these distances The standard clearance without these would revert to 900mm Combustible material refers to any material that will degrade when subjected to heat e g plaster Heat Shield Top Heat Shield Rear And Top Heat Shield 4 4 C 5 5 C 5S 6 7 8S 8 9 14 Behind the stove 200mm 100mm 200mm 200mm 200mm 150mm 300mm 200mm 250mm 125mm 2...

Page 18: ... left hand edge clear of the stove body and remove To fit the heat shield for the Slimline s and 8 position the left hand edge and then flex the heat shield until the right hand edge clears the stove body and pops into place Insert and lightly tighten the supplied button head screw to prevent any rattle Do not over tighten the screw as this will damage the heat shield All others are placed on the ...

Page 19: ...with all of the windows and doors to the room where the appliance is fitted closed If there are any adjoining room s that have an Extractor Fan fitted open the adjoining door to ensure that the chimney flue system is not compromised when the fan is operating If there is a ceiling fan fitted in the room please operate it and ensure that it does not affect the operation of the chimney flue system If...

Page 20: ...ection 16 of the Environmental Better regulation Act Northern Ireland 2016 In Wales appliances are exempted by regulations made by Welsh Ministers Further information on the requirements of the Clean Air Act can be found here https www gov uk smoke control area rules Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control a...

Page 21: ... a traditional stove if used correctly with the obvious notable feature of CLEAN GLASS It is essential that the stove has an adequate air supply for combustion and ventilation A When the air control rod is pushed in fully then both the Primary and Secondary air intakes are in the closed position B To operate pull the air control rod away from the stove For the air control to be in the fully open p...

Page 22: ...e fire pull the air control rod until it is fully open B then push it in halfway for normal burning C Warning The stove will remain hot for a considerable time after the fire has been extinguished Notes on Woodburning With a full load of wood the stove will need to be refuelled approximately once every hour Wood can be stacked in the stove but no higher than the tertiary air holes at the back of t...

Page 23: ...h as during the spring and summer months a competent person should check the chimney for potential obstructions before lighting the stove i e get the chimney swept before the start of the heating season Baffle This should be removed and cleaned at least once a month to prevent any build up of soot or fly ash that could lead to blocked flue ways and dangerous fume emission If the baffle is removed ...

Page 24: ...ogs are continually jammed against them or if they are frequently struck with a poker Check periodically for seriously cracked bricks which can be replaced with new available from your dealer or our spares website www hunterstoves co uk spares Door Catch Assembly Changing The Door Handle Remove screw holding in door hook with a flat head screwdriver Pull hook out of hole in door To change the door...

Page 25: ...any delay in receiving replacement components should you need them If you feel unable to undertake this task Hunter Stoves recommend that you contact the installation engineer for advice Remove all the internal components Log retainer bricks ignition air bar baffle Clean them with a soft brush carefully and inspect them for damage Sweep the chimney flue system if necessary Clean down the internal ...

Page 26: ...ve smoke spillage into room when appliance door is opened Low flue draught Speak to your installer Incorrect additional ventilation air in to the building Speak to your installer Continuous smoke spillage into the room when stove is in use Blocked flue Open all doors and windows to ventilate the room Allow the fire to go out Check flue for blockage Do not re use until the problem has been identifi...

Page 27: ...re content over 20 Use dry seasoned wood less than 20 moisture content Glass blackening Using poor quality wood Use dry seasoned wood less than 20 moisture content Low flue draught Speak to your installer Incorrect use of air control See user instructions for correct use of air control Appliance operated at low temperatures continuously Operate at high output for short periods See instructions for...

Page 28: ...amper taller flue collar needed CH05010 HHR99992 MULTIFUEL CONVERSION KITS Aspect 4 JPA04 Aspect 4 Compact JPA04C Aspect 5 JPA05 Aspect 5 Compact JPA05C Aspect 5 Slimline JPA05S Aspect 6 JPA06 Aspect 7 JPA07 Aspect 8 Slimline JPA08S Aspect 8 JPA08 Aspect 9 JPA09 Aspect 14 JPA14 FLUE HEAT SHIELD Aspect 4s ECIC04047 Aspect 5s 7 ECIC05031 Aspect 5 Slimline 6 9 14 ECIS05054 Aspect 8 8 Slimline ECIS080...

Page 29: ... 4 COMPACT ASPECT 4 DOOR FRONT VIEW ASPECT 4 COMPACT ASPECT 4 DOOR REAR VIEW ASPECT 5 COMPACT ASPECT 5 DOOR FRONT VIEW ASPECT 5 COMPACT ASPECT 5 DOOR REAR VIEW ASPECT 5 SLIMLINE 6 DOOR FRONT VIEW ASPECT 5 SLIMLINE 6 DOOR REAR VIEW ...

Page 30: ...30 ASPECT 7 DOOR FRONT VIEW ASPECT 7 DOOR REAR VIEW ASPECT 8 8 SLIMLINE 9 AND 14 DOOR FRONT VIEW ASPECT 8 8 SLIMLINE 9 AND 14 DOOR REAR VIEW BODY ASSEMBLY SPARES ASPECT COMPACT 4 AND 4 ...

Page 31: ...31 BODY ASSEMBLY SPARES ASPECT COMPACT 5 AND 5 BODY ASSEMBLY SPARES ASPECT 5 SLIMLINE ...

Page 32: ...32 BODY ASSEMBLY SPARES ASPECT 6 BODY ASSEMBLY SPARES ASPECT 7 ...

Page 33: ...33 BODY ASSEMBLY SPARES ASPECT 8 BODY ASSEMBLY SPARES ASPECT 8 SLIMLINE ...

Page 34: ...34 BODY ASSEMBLY SPARES ASPECT 9 BODY ASSEMBLY SPARES ASPECT 14 ...

Page 35: ...Description Serial Number COMMISSIONING CHECK Complete Sign YES NO Does the chimney flue system meet the appropriate standard Has the chimney flue system been swept and passed the soundness test Has this appliance passed the flue draught test Please write down the flue draught reading Has this appliance passed the smoke test Has this appliance passed the spillage test Have you explained how to ope...

Page 36: ...gnature 9th Service Date of Service Date of next Service Servicing Company Engineer Signature 2nd Service Date of Service Date of next Service Servicing Company Engineer Signature 4th Service Date of Service Date of next Service Servicing Company Engineer Signature 6th Service Date of Service Date of next Service Servicing Company Engineer Signature 8th Service Date of Service Date of next Service...

Page 37: ... 12 months of the installation date for the second year of the standard warranty to be valid and within every 12 month anniversary thereafter to maintain the validity and coverage of any extended warranty For this purpose the installation and user instructions supplied with the appliance makes a provision for receipts and annual services to be recorded This is needed in the event of a claim during...

Page 38: ...associated non Hunter Stoves Group products is not covered under the warranty 6 Consequential loss relating to decorations soft furnishings or other household assets is not covered under the warranty 7 Cost associated with the removal and re installation of an appliance subject to a warranty claim Hunter Stoves Group total liability will only extend to the total purchase price paid for the goods i...

Reviews: