Parker WCS-SIF-01 Training & Maintenance Manual Download Page 12

1

WCS-SIF-01

Training & Maintenance Manual

Pneumatic

Parker Hannifin Corporation

Pneumatic Division

Richland, Michigan

www.parker.com/pneumatics

How To Order Add-A-Fold 
Assemblies

1. List Add-A-Fold Assembly call out. This automatically  
  includes the end plate kit assembly.
. List complete Valve and Base model number. List left to  
  right, LOOKING AT THE CYLINDER PORTS on the #1  
  end of the manifold.  The left most station is station 1.

Station 2

Station 1

#14 End

#12 End

Example

Application requires a -Station manifold with weld block and 
valves, and requires isolation between station 1 and  for port 
#3 galley only.

 

Item  Qty.  Part  No.

  01 

AAHE00

  0 

HVXHG0B9C ...................................Station 1 & 

  03 

 

PS411157MCP ....................................Station 1 & 

  04 

WPJ1XXXN .................................................Station 

  05 

HEVXHG0B9C ..........................................Station 

  06 

PS363P .....Galley 3 Isolation Between Station 1 & 

Valve Series

  H2 Right & Left  
   

End Plate

Port Type

  0  NPT
  1  BSPP “G”

 

 

Valve  

End Plate 

Port 

Number of

 

 

Series 

Type 

Type 

Stations

 AA 

H2 

02

Add-A-Fold Assembly Model Number

Example: 

2-Station Manifold with (2) H2 Valves 

On Manifold Bases

End Plate Type

 

D

  25-Pin

  E

  19-Pin

  G

  M3, 1-Pin

 

S  Standard - 

   

Non-collective Wiring

†  Collective Wiring Module 

Included.

NOTE:

 Construct manifold assemblies from left to right while looking at 

the cylinder ports.

Ordering Information

Number of 

Stations

02

*  Only Available 

with -Station 
Manifold when 
Used in Welding 
Applications.

Summary of Contents for WCS-SIF-01

Page 1: ...Pneumatic Spotwelding Control Systems Training Maintenance Manual WCS SIF 01 Training Maintenance Manual ISSUED November 2006 Supersedes June 2006 Pneumatic Division Richland Michigan 49083...

Page 2: ...ll lengthen time until it reaches a full 360 rotation which covers the complete timing range 3 The weld stroke valve is then energized using a selected weld schedule pressure The closure speed of the...

Page 3: ...ld cycle 4 Once the weld cycle is complete the weld stroke valve is de energized allowing the weld tips to open under full pressure 5 The retract pre stroke valve is then de energized allowing the wel...

Page 4: ...air supply and power on 9 Check for air leaks The weld cylinder should be in the home position completely open If not check that all air hoses are connected to the correct ports Verify that all solen...

Page 5: ...ause the flow control has been opened so much that all the air on the front side of the cylinder has exhausted before the tips fully close thus negating the low impact benefit of the system To guarant...

Page 6: ...nd dried to a dewpoint of 37 F 3 C lubricated or non lubricated Once lubricated air is applied this must be maintained Working Pressure 37 to 145 PSIG 2 5 to 10 bar WH Series Air Operated Quick Exhaus...

Page 7: ...oil F 24VDC M12 Connector X Without Valves N NPT G BSPP A 120VAC 22mm Coil B 120VAC 30mm Coil D 24VDC 22mm Coil E 24VDC 30mm Coil F 24VDC M12 Connector X Without Valves 4 Valve Block High Pressure Qui...

Page 8: ...k Quick Exhaust Mounted Cylinder Mount B Valve Block w Base Plate Air Operated High Flow Quick Exhaust G Valve Block w Base Plate High Pressure Quick Exhaust H Valve Block w Base Plate Solenoid Operat...

Page 9: ...lve Block w o Weld Stroke Valve K Valve Block ISO Manifold Mountable Plug In Air Operated High Flow Quick Exhaust L Valve Block ISO Manifold Mountable Plug In Solenoid Operated High Flow Quick Exhaust...

Page 10: ...st Lights Length Frequency Options Level H2 E WX H B L 49 C Ordering Information BOLD OPTIONS ARE MOST POPULAR 5599 1 Pilot Source Pilot Exhaust H 5 Port Vented 5599 1 Operator Function 2 Double Solen...

Page 11: ...Ford G General Motors Mounting Base Style Enclosures Wiring Engineering Factory Basic Series Port Size Lead Length Options Level Designator PS4111 55 A C P Engineering Level C Current Enclosures Lead...

Page 12: ...ion 1 and 2 for port 3 galley only Item Qty Part No 01 1 AAH2E002 02 1 H22VXHG0B9C Station 1 2 03 2 PS411157MCP Station 1 2 04 1 WPJ1XXXN Station 2 05 1 H2EVXHG0B9C Station 2 06 1 PS3632P Galley 3 Iso...

Page 13: ...ions 1 1 Station Manifold2 2 2 Station Manifold2 5 Single Subbase2 Basic Valve Manifold Engineering Series Series Protocol Subbase Stations Power I O Options Level S3 H2 D 2 D 0 C Engineering Level C...

Page 14: ...lb Torque 4 115 to 130 in lb Torque 4 85 to 100 in lb Torque 85 to 100 in lb Torque 6 8 Not Shown 9 Bore Lightly grease with provided lubricant Inspect for nicks scratches and surface imperfections I...

Page 15: ...8 5 50 1 5 4 9 7 3 0 9 58 7 10 19 136 5 35 9 0 35 50 7 00 1 7 3 5 01 10 4 0 8 1 10 44 8 1 76 8 1 10 58 8 31 11 5 0 45 81 5 3 1 9 5 1 16 15 0 59 33 1 30 B6 Series Dimensions mm inches 0 1 0 1 100 ED 1...

Page 16: ...er com pneumatics WH Series For 3 Ported Gun Dimensions mm inches 170 5 6 71 48 65 9 79 19 3 7 57 67 64 36 1 4 34 5 1 36 136 5 35 100 3 94 15 0 59 55 17 76 99 79 5 3 1 88 3 46 9 0 35 136 5 35 1 75 0 5...

Page 17: ...arker com pneumatics WH Series For 3 Ported Gun Dimensions mm inches 170 5 6 71 19 3 7 57 15 0 59 55 17 79 5 3 1 88 3 46 9 0 35 136 5 35 1 75 0 50 145 5 71 Pr Pw R R W W X I 12 X I 12 X I 14 1 0 PRESS...

Page 18: ...4 Ported Gun Dimensions WP ISO Size 2 Manifold Mountable X I 12 X 14 1 0 PRESS 58 8 109 5 4 31 31 5 1 4 16 1 0 63 63 48 3 1 6 88 8 3 49 46 5 1 83 146 7 5 78 80 7 3 18 187 5 7 38 08 7 8 WH ISO Size 2 M...

Page 19: ...Also verify feedback sensor is operating properly 4 Weld gun fires before tips are closed Adjust flow control so that weld tips close slower See Setup Instructions on page 5 Is sensor input in the PL...