4. CONTROL OF VIX DRIVES 65
Torque Mode Commands
For the ViX drive issue the following commands:
1MT
;Mode Torque
1W(ES,0)
;Energise input active level
1GAINS(0,0,0,0,0)
;Zero all gains
1SV
;Save settings
A valid MOTOR command is required.
All GAINS need to be 0.0
For the 6K4 issue the following commands:
AXSDEF1111
All axes are steppers
ERES8000,8000,8000,8000
Should match V
i
X motor resolution
DRFLVL1111
Drive fault active level
DRFEN1
Enable drive fault detection
LH0,0,0,0
Disable limits (optional)
TGAIN
Read all gains
SGP
Set proportional gain
SVG
Set velocity gain
A
V
D
GO1
Execute move