94
VIX AH SERVO DRIVE USER GUIDE
Properties
Immediate, saved by SV
Note
[1] If the thermal time constant is set to zero, the I
2
t protection for the motor
is disabled.
[2] The motor command can take up to 10 seconds to finish execution.
[3] The drive will not be allowed to energise without a valid motor command
being executed.
R
Report system parameter
Syntax
Units
Range of ‘n’
Default
See also
aR(system_variable)
-
-
-
W, R
Description
The R command allows the user to read the specified system variable.
Properties
Immediate, not saved by SV
Example
2W(TL,4000))
;set variable TL (Tracking Limit) to be 4000
2R(TL)
;report the current value of variable TL
The response will be ........................................................ *4000
Note
See table of system variables.