8
Specifications
1000FH
Maximum Flow Rate:
180 GPH (681 LPH)
Port Size
7/8"-14 UNF
(SAE J1926)
(female threads)
Minimum Service Clearance:
(Above Assembly)
(Below Assembly)
10.0 in. (25.4 cm)
2.0 in. (5.1 cm)
Replacement Filter:
(2 micron)
(10 micron)
(30 micron)
(1 Per Assembly)
New: 2020N-02 (Old: 2020SM-OR)
New: 2020N-10 (Old: 2020TM-OR)
New: 2020N-30 (Old: 2020PM-OR)
Height
22.0 in. (55.9 cm)
Depth
7.0 in. (17.8 cm)
Width
6.0 in. (15.2 cm)
Weight (dry)
10.0 lb (4.5 kg)
Clean Pressure Drop
0.43 PSI (0.03 bar)
Maximum Pressure
1
15 PSI (1.03 bar)
Water In Bowl Capacity:
10.3 oz (305 ml)
Available Options:
(water detection kit)
2
(12 or 24 volt dc heater)
2
(vacuum gauge)
(12 or 24 vdc primer pump)
Yes
Yes
Yes
Yes
Water Removal Efficiency
99%
Ambient Temperature Range
-40
o
to +255
o
F (-40
o
to +124
o
C)
Maximum
Fuel Temperature
190°F (88°C)
1
Pressure installations are applicable up to the maximum PSI shown.
Vacuum installations are recommended.
2
Not for use on gasoline applications.
1000FH