background image

Page 3

Pressing the 

UP

 button will open the valve 100 steps.

Pressing the 

DOWN

 button will close the valve 100 steps.

Pressing the 

ENTER

 button will change the flashing digit from 100’s digit 

to the 10’s digit.
Pressing the 

UP

 button will open the valve 10 steps.

Pressing the 

DOWN

 button will close the valve 10 steps.

Pressing the 

ENTER

 button will change the flashing digit from 10’s digit 

to the 1’s digit.
Pressing the 

UP

 button will open the valve 1 step.

Pressing the 

DOWN

 button will close the valve 1 step.

Pressing the 

ENTER

 button will change the flashing digit from 1’s digit 

to the 1000’s digit.
Press and hold the 

UP

 button and 

ENTER

 button together for 5 seconds to 

put the controller in normal control. The digits will stop blinking.

SSP1 MODE

Press and hold the 

UP

 button and 

ENTER

 button for 5 seconds to enable 

the superheat set point to be changed. The set point is displayed and the 

100’s digit will blink.
Pressing the 

UP

 button will increase the set point by 100 degrees.  

Pressing the 

DOWN

 button will decrease the set point by 100 degrees.  

Pressing the 

ENTER

 button will change the flashing digit from 100’s digit 

to the 10’s digit.
Pressing the 

UP

 button will increase the set point by 10 degrees.

Pressing the 

DOWN

 button will decrease the set point by 10 degrees.

Pressing the 

ENTER

 button will change the flashing digit from 10’s digit 

to the 1’s digit.
Pressing the 

UP

 button will increase the set point by 1 degree.

Pressing the 

DOWN

 button will decrease the set point by 1 degree.

Pressing the 

ENTER

 button will change the flashing digit from 1’s digit 

to the 100’s digit.
Press and hold the 

UP

 button and 

ENTER

 button together for 5 seconds 

to save the set point. The digits will stop blinking.

MOP1 MODE

Press and hold the 

UP

 button and 

ENTER

 button for 5 seconds to enable 

the Maximum Operating suction Pressure set point to be changed. The set 

point is displayed and the 100’s digit will blink.
Pressing the 

UP

 button will increase the set point by 100 PSI.

Pressing the 

DOWN

 button will decrease the set point by 100 PSI.

Pressing the 

ENTER

 button will change the flashing digit from 100’s digit 

to the 10’s digit.
Pressing the 

UP

 button will increase the set point by 10 PSI.

Pressing the 

DOWN

 button will decrease the set point by 10 PSI.

Pressing the 

ENTER

 button will change the flashing digit from 10’s digit 

to the 1’s digit.
Pressing the 

UP

 button will increase the set point by 1 PSI.

Pressing the 

DOWN

 button will decrease the set point by 1 PSI.

Pressing the 

ENTER

 button will change the flashing digit from 1’s digit 

to the 100’s digit.
Press and hold the 

UP

 button and 

ENTER

 button for 5 seconds to save the 

set point. The digits will stop blinking.

CTS1 MODE

Press and hold the 

UP

 button and 

ENTER

 button for 5 seconds to enable 

the cut out suction pressure set point to be changed. The set point is dis-

played and the 100’s digit will blink.
Pressing the 

UP

 button will increase the set point by 100 PSI.

Pressing the 

DOWN

 button will decrease the set point by 100 PSI.

Pressing the 

ENTER

 button will change the flashing digit from 100’s digit 

to the 10’s digit.
Pressing the 

UP

 button will increase the set point by 10 PSI.

Pressing the 

DOWN

 button will decrease the set point by 10 PSI.

Pressing the 

ENTER

 button will change the flashing digit from 10’s digit 

to the 1’s digit.

Pressing the 

UP

 button will increase the set point by 1 PSI.

Pressing the 

DOWN

 button will decrease the set point by 1 PSI.

Pressing the 

ENTER

 button will change the flashing digit from 1’s digit 

to the 100’s digit.
Press and hold the 

UP

 button and 

ENTER

 button for 5 seconds to save the 

set point. The digits will stop blinking.

NOTE:

 

CTS1

 set point is used to help stop nuisance, low suction pressure 

trips of the compressor. If the suction pressure goes below CST1, and the 

superheat is above the superheat set point, the valve will keep opening 

until the suction pressure is above CST1 or the superheat is below its set 

point. The controller will start controlling superheat from this new valve 

position. If the superheat is below its set point and the suction pressure 

is below this set point, the controller will change CST1 to 12 PSI below 

current suction pressure. If power is lost, the original saved set point is 

used again.
When in 

CLP1 or CLT1

, the numeric display shows the PSI or degrees to 

be either added or subtracted from that particular sensor, depending if the 

reading is negative or positive. Press and hold the 

UP

 button and 

ENTER

 

button for 5 seconds to enable the sensor to be calibrated.
The 

CAL

 number is displayed and the 10’s digit will blink.

Pressing the 

UP

 button will increase the CAL number by 10 PSI or degrees.

Pressing the 

DOWN

 button will decrease the CAL number by 10 PSI or 

degrees.

Pressing the 

ENTER

 button will change the flashing digit from 10’s digit to 

the 1’s digit.
Pressing the 

UP

 button will increase the CAL number by 1 PSI or degree.

Pressing the 

DOWN

 button will decrease the CAL number by 1 PSI or 

degree.

Pressing the 

ENTER

 button will change the flashing digit from 1’s digit 

to the 0.1’s digit.
Pressing the 

UP

 button will increase the CAL number by 0.2 PSI or degree.

Pressing the 

DOWN

 button will decrease the CAL number by 0.2 PSI 

or degree.

Pressing the 

ENTER

 button will change the flashing digit from 0.1’s digit 

to the 10’s digit.
Press and hold the 

UP

 button and 

ENTER

 button for 5 seconds to save the 

CAL number. The digits will stop blinking.

PRO1, INT1, DER1, DON1, DOF1 AND DST1
SETTING PROCEDURE 

Use the 

UP

 and 

DOWN

 buttons to scroll to the Setpoint to be changed.

Press and hold the 

UP

 button and 

ENTER

 button for 5 seconds to allow 

set point to be changed. The set point is displayed and the 100’s digit will 

blink.
Pressing the 

UP

 button will increase the set point by 100 units.

Pressing the 

DOWN

 button will decrease the set point by 100 units. 

Pressing the 

ENTER

 button will change the flashing digit from 100’s digit 

the 10’s digit.
Pressing the 

UP

 button will increase the set point by 10 units.

Pressing the 

DOWN

 button will decrease the set point by 10 units.

Pressing the 

ENTER

 button will change the flashing digit from 10’s digit 

to the 1’s digit.