Installation and servicing manual

Low pressure pump, QPM3

 

10

Parker Hannifin Corporation

Hydraulics Group

Catalogue HY10-6012-UM/EU

Installation/Handling

Installation

Lifting
 

 Caution

 Risk of bodily injury. To prevent bodily injury when 

lifting the pump, ensure correct lifting technique is used. 

Make sure that all lifting devices are working properly and 

that they are approved for the weight of the pump. Use 

lifting straps under the pump unit to prevent bodily injury.

Mounting
 

 Precaution 

Risk of bodily injury. Make sure that all parts of 

the pump are firmly secured.

An upright position of the QPM3 pump, standing on the electric mo-

tor feet is recommended.

The pump can be mounted in any position in steps of 90° in relation 

to the electric motor.

To achieve optimum pump capacity, install the unit below tank oil le-

vel (max. 5 meter) and as close to the tank as possible. When instal-

led above tank oil level, minimize the difference in height and install 

a check valve or shut-off valve at the pump inlet. Place the unit to 

ensure adequate air flow through the electric motor.

The acoustic pressure level could reach 65-67 dB(A) LpA at a dis-

tance of 1 m under normal conditions. Inappropriate location or ope-

ration under extreme conditions could generate increased acoustic 

power level.

Oil connection

Connect the QPM3 low pressure pump using flexible hydraulic 

hoses. Make sure that all connections and hoses are sized 

according to the system pressure, flow, temperature and type of 

oil. Connect the hydraulic hoses as illustrated 

in figure 2.

A

 – Inlet. 

B

 – Outlet.

Maximum permitted oil temperature is 100 °C.

The size of the inlet line should not be inferior to the pump 

connection size. A larger size is recommended.

Avoid flow rates in excess of 1 m/s in the pump inlet line.

Maximum pressure on the pump suction side is 0.5 bar.

Maximum suction pressure in the pump inlet line with oil filled pump 

is 0.4 bar.

Parker will not be held responsible for the consequences of any 

modification or variation with regard to connections.

Electrical connection

 

 Danger Electrical shock hazard. All electrical connections 

must be made by a qualified electrician!

Prior to connecting the motor to the electrical supply system, 

make sure that the specification on the electric motor rating plate 

corresponds to the mains supply voltage and frequency. The 

electric motor should be installed according to general rules and 

electrical safety regulations and must be installed by a qualified 

electrician.
  

Caution

 Risk of personal injury and damage to property. 

Be careful when connecting the equipment. Improperly 

made connections, damaged cables, etc. could cause 

parts to become current carrying or result in incorrect 

direction of rotation of the electric motor and pump. 

See Figure 3.

Important

 Do not exceed the maximum rated current for the 

electric motor, 

see electric motor rating plate.

Note!

 An electric motor overload protection is recommended.

In extremely humid environments, especially when the operation 

is intermittent, condensation may form. Some motors are fitted 

with plugged holes, which can be used to drain condensed water. 

Depending on the placement of the electric motor, proper plugs 

should be removed.

If the QPM3 low pressure pump is installed in an environment 

where water may penetrate into the electric motor, use a protective 

shield. The protective shield is available as an option.

Handling

Prior to initial start-up
 

 Precaution

 Make sure that the unit is securely fixed and 

correctly connected. We recommend to run the pump with 

the same oil as used in the hydraulic system. 

See Technical 

specification for oil compatibility.

Note!

 Air in the inlet line could sometimes cause problems at initial 

start-up. Make sure that the pump inlet is always filled with oil.

Prior to start up
 

 Precaution

 DMake sure that the pump can be put into 

service without causing bodily injury or damage to property 

or environment.

Make sure that:

• ltall hydraulic connections are tight,

•  valves and similar throttling devices are open and

that conduits and couplings are not damaged.

At start-up

Make sure that:

•  the  direction  of  rotation  corresponds  to  indications  on  the 

pump cover by looking at the electric motor fan, 

see Figure 4,

• the oil filter is free from abnormal noise and vibrations.
Make sure not to overload the electric motor due to cold start 

conditions or operation with high oil viscosity.

Recommended operating viscosity range is 10 – 800 cSt con-

sidering the motor power. Consult your local Parker office when 

using high viscosity oils or when the pump is operating in cold 

start condition.

For long service life, oil cleanliness should, according to ISO 

4406, not be below 17/15.

Note! 

Air in the inlet line could cause problem at start-up.

Make sure that the pump inlet is always filled with oil.

During operation
 

 Caution

 Risk of personal injury and damage to property. 

The pump must not be run in such a way that the maximum 

pressure is exceeded, which could occur if the pump outlet 

is closed or severely throttled. This could damage the unit 

and cause personal injury.

Important

 Risk of heat release. Avoid internal recirculation during 

a long period of time.

Note!

 Use hearing protection when standing in the immediate 

vicinity of an operating pump for long periods of time.
The pump is not provided with by-pass valve as standard.

Use pump with by-pass valve if the system is provided with shut-

off valves etc. or if the pump is exposed to cold starts.

Pump with internal or external by-pass valve is available as option.

Summary of Contents for QPM3

Page 1: ...Air Oil Coolers QPM3 Low pressure pump Installation and servicing manual aerospace climate control electromechanical filtration fluid gas handling hydraulics pneumatics process control sealing shielding ...

Page 2: ...Equipamientos opcionales A Válvula bypass interna 5 bar o 10 bar B Válvula bypass externa 5 bar o 10 bar Rosca macho G C Placa protectora motor eléctrico no aparece en la figura A B Tillval A Intern bypassventil 5 eller 10 bar B Extern bypassventil 5 eller 10 bar Gänganslutning utvändig G C Skyddsplåt för elmotor ej med på bild Options A Internal bypass valve 5 or 10 bar B External bypass valve 5 ...

Page 3: ... Technical specification 12 Declaration of conformity 13 Einleitung 14 Sicherheitsvorschriften 14 Beschreibung 15 Installation 15 Bedienung 16 Vorbeugende Wartung 16 Wartung 17 Technische Daten 18 Konformitätserklärung 19 Introduction 20 Consignes de sécurité 20 Description 21 Installation 21 Consignes d emploi 22 Entretien préventif 22 Entretien 23 Caractéristiques techniques 24 Déclaration de co...

Page 4: ...t inträffa om föreskrif ten inte följs Olyckan kan leda till skada på egendom process eller omgivning gällande tilläggsinformation Tilläggsinformation markeras enligt följande Anm Anger extra information som kan underlätta förståelse för eller utförande av ett visst moment Övergripande föreskrifter Varning Risk för personskada Koppla alltid bort driv käl lan för motorn innan underhåll Varning Risk...

Page 5: ...er och fel rotationsriktning på motor och pump Se Bild 3 Viktigt Elmotorns märkström får inte överskridas Se märkplåt på elmotorn Anm Parker rekommenderar att använda överströmsskydd för elmotorn I mycket fuktig miljö speciellt i samband med intermittent drift kan kondensvatten bildas i elmotorn Vissa elmotorer är försedda med pluggade hål som kan användas som utlopp för eventuellt kondensvatten B...

Page 6: ...ruvarna med brickor som håller pumpen till elmotorn 7 Tag bort pumpen och kopplingens kuggkrans Pumpen och kopplingsdelarna kan nu bytas ut 8 Lossa stoppskruven T i axelkopplingsdelen om sådan finns Ta bort axelkopplingsdelen från elmotoraxeln Se Bild 6 B Anm Vissa elmotorer kan ha en eller flera adapterplattor Vid byte av elmotor skruva ur skruvarna som håller adapterplat torna till elmotorn Ta b...

Page 7: ... QPM3 80 2 20 80 28 67 QPM3 80 3 00 80 28 67 Teknisk data Tekniska data Vikten varierar med motorfabrikat Ljudnivåtolerans 3 dB A Pump Maximalt arbetstryck Maximalt tillåten oljetemperatur Kompatibilitet Mineralolja Syntetiska oljor Vegetabiliska oljor Turbinoljor Vid drift med andra oljor eller vid extrema driftsförhållanden kontakta Parker Material Pumpenhet Aluminium stål O ringar och packninga...

Page 8: ...directives Safety of machinery Basic concepts general principles for design SS EN ISO 12100 1 A1 2009 and SS EN ISO 12100 2 A1 2009 Safety of machinery Safety requirements for fluid power systems and their components Hydraulics SS EN ISO 4413 2010 Pumps and pump units for liquids Common safety requirements SS EN 809 A1 2009 AC 2010 Electric motors used on the product comply with the Low Voltage Di...

Page 9: ...ss or environment concerning additional information Additional information is marked as follows Note This alerts you to important information related to the text in a paragraph Overall instructions Danger Electrical shock hazard All electrical connections must be made by a qualified electrician Caution Risk of bodily injury Disconnect the motor power supply prior to maintenance Caution Risk of bod...

Page 10: ...come current carrying or result in incorrect direction of rotation of the electric motor and pump See Figure 3 Important Do not exceed the maximum rated current for the electric motor see electric motor rating plate Note An electric motor overload protection is recommended In extremely humid environments especially when the operation is intermittent condensation may form Some motors are fitted wit...

Page 11: ...move the screws and washers fixing the pump to the electric motor 7 Remove the pump and the gear rim The pump and the coupling details can now be replaced 8 Loosen the stop screw T if any in the shaft coupling detail See Figure 6 B Remove the shaft coupling detail from the crankshaft Note Certain motors have one or more adapter plates To remove the electric motor remove the screws fixing the adapt...

Page 12: ...0 80 28 67 QPM3 80 3 00 80 28 67 Technical specification The weight depends on motor make Noise level tolerance 3 dB A Pump Max working pressure 10 bar Max permitted oil temperature 100 C Compatibility Mineral oil Synthetic oils Vegetable oils oljor Turbine oils Contact your local Parker office for operation with other oils or operation under extreme conditions Material QPM3 low pressure pump Alum...

Page 13: ...rectives Safety of machinery Basic concepts general principles for design SS EN ISO 12100 1 A1 2009 and SS EN ISO 12100 2 A1 2009 Safety of machinery Safety requirements for fluid power systems and their components Hydraulics SS EN ISO 4413 2010 Pumps and pump units for liquids Common safety requirements SS EN 809 A1 2009 AC 2010 Electric motors used on the product comply with the Low Voltage Dire...

Page 14: ...nstigen Sicherheit Vorsichtshinweise die mit sonstiger Sicherheit Güter Prozesse oder Umgebung und Handhabung zu tun haben sind wie folgt klassifiziert Wichtig bedeutet dass ein Unfall eintreffen kann wenn die Vorschrift nicht befolgt wird Der Unfall kann zu Schäden an Gütern Prozessen oder der Umgebung führen zu Zusatzinformationen Die Zusatzangaben werden wie folgt gekennzeichnet Hinweis Gibt zu...

Page 15: ... Im Abstand von 1 m kann der Schalldruckpegel unter normalen Betriebsbedingungen bis zu 65 67 dB A LpA betragen Eine ungünstige Aufstellung oder der Betrieb unter extremen Be dingungen kann zu einem erhöhten Schalldruckpegel führen Ölanschluss A Eintritt B Austritt Die max zulässige Öltemperatur beträgt 100 C Der Durchmesser der Eintrittsleitung muss mindestens genauso groß sein wie der Anschlussd...

Page 16: ...iebnahme führen Darauf achten dass die Eintrittsleitung stets mit Öl gefüllt ist Während des Betriebs Warnung Gefahr von Verletzungen und Sachschäden Beim Betrieb der Pumpe darf der max zulässige Druck nicht überschritten werden Dies kann der Fall sein wenn die Ölleitung an der Austrittsseite der Pumpe geschlossen oder stark gedrosselt ist was zu Schäden an der Pumpe und Verletzungen führen kann W...

Page 17: ...uben die die Pumpe mit dem Elektromotor verbinden mit Unterlegscheiben versehen und festschrauben 8 10 Nm 8 Hydraulikschläuche an das Gerät anschließen 9 Die Öleintritt und austritt anschließen 10 Motor an die Antriebsquelle anschließen 11 Die in den Kapiteln Vor dem Start und Beim Start beschrie benen Schritte ausführen Wartung Parker haftet nicht für die Folgen von Reparaturen oder Umbauten die ...

Page 18: ... 80 28 67 QPM3 80 3 00 80 28 67 Technische Daten Das Gewicht hängt vom Fabrikat des Motors ab Toleranz Geräuschpegel 3 dB A Pumpe Maximaler Betriebsdruck 10 bar Maximal zulässige Öltemperatur 100 C Kompatibilität Mineralöl Synthetische Öle Pflanzliche Öle Turbinenöle Vor der Verwendung anderer Öle oder bei extremen Betriebsbedingungen Kontakt mit Parker aufnehmen Werkstoffe Pumpe Aluminium Stahl O...

Page 19: ...ctives Safety of machinery Basic concepts general principles for design SS EN ISO 12100 1 A1 2009 and SS EN ISO 12100 2 A1 2009 Safety of machinery Safety requirements for fluid power systems and their components Hydraulics SS EN ISO 4413 2010 Pumps and pump units for liquids Common safety requirements SS EN 809 A1 2009 AC 2010 Electric motors used on the product comply with the Low Voltage Direct...

Page 20: ...t accident peut entraîner des blessures corporelles relatifs aux autres aspects de la sécurité Les textes de mise en garde relatifs aux autres aspects de la sécurité biens procédés ou environnements et à la manipula tion du produit sont classés comme suit Important indique qu un accident peut se produire en cas de non respect de la consigne Cet accident peut entraîner des dom mages aux biens au pr...

Page 21: ...d entraîner une pression acoustique élevée Connexion d huile Utilisez des flexibles hydrauliques pour raccorder la pompe basse pression QPM3 S assurer que tous les raccords et flexibles sont dimensionnés suivant la pression le débit la température et le type d huile du système Raccordez les flexibles hydrauliques comme suit Voir Figure 4 A Entrée B Sortie La température maximale autorisée de l hui...

Page 22: ...causer des problèmes au démarrage Dans ce cas remplissez le avec de l huile Pendant le fonctionnement Avertissement Risque de blessures corporelles et dom mages aux biens La pompe QPM3 ne doit pas être utilisée dans des conditions qui pourraient engendrer des niveaux de pressions supérieurs aux pressions admissibles dans la pompe Ceci peut se produire si le circuit sur le côté sor tie de la pompe ...

Page 23: ...tions au moteur électrique Retirer les plaques d adaptations Montage de la pompe et du raccord au moteur électrique Voir Figure 5 Danger Risque d électrocution Toute connexion électrique doit être effectuée par un électricien agrée 1 Déposer la partie de l arbre du raccord sur l arbre du moteur électrique Serrer éventuellement le vis d arrêt Voir Figure 6 B 2 Moteur 80 Presser la partie de l accou...

Page 24: ...tiques techniques Varie suivant le fabricant du moteur Tolérance de niveau de bruit 3 dB A Pompe Pression de service maxi 10 bar Température d huile maxi autorisée 100 C Compatibilité Huile minérale Huiles synthétiques Huiles végétales Huiles pour turbines Consultez Parker en cas d utilisation d autres huiles ou d une utilisation dans des conditions extrêmes Matériaux Pompe Aluminium acier O Ringe...

Page 25: ...rectives Safety of machinery Basic concepts general principles for design SS EN ISO 12100 1 A1 2009 and SS EN ISO 12100 2 A1 2009 Safety of machinery Safety requirements for fluid power systems and their components Hydraulics SS EN ISO 4413 2010 Pumps and pump units for liquids Common safety requirements SS EN 809 A1 2009 AC 2010 Electric motors used on the product comply with the Low Voltage Dire...

Page 26: ...idad Las indicaciones de seguridad concernientes a otros aspectos de seguridad propiedad proceso medio ambiente y a la mani pulación del producto están clasificadas como sigue Importante alerta que una acción o procedimiento realizado inco rrectamente puede provocar daños en el equipo al proceso o al medio ambiente relativos a las infórmaciones complementarias Las informaciones complementarias est...

Page 27: ...acústica puede alcanzar 65 67 dB A LpA a 1 m de distancia bajo condiciones de funcionamiento normales Un emplazamiento inadecuado puede provocar un nivel de potencia acústica elevada Conexión del aceite Utilizar flexibles hidráulicos para la conexión de la bomba QPM3 Asegurarse de que los rácords y los flexibles estén dimensiona dos y sean adecuados a la presión al caudal a la temperatura y tipo d...

Page 28: ...lemas en el arranque inicial En este caso llenar la tubería con aceite Durante el funcionamiento Advertencia Riesgo de heridas corporales y daños al producto La bomba QPM3 no puede utilizarse en aqu ellas condiciones en que podrían originarse presiones superiores a la máxima presión permitida Esto puede ocurrir si la salida de la bomba está cerrada o severa mente obstruida Esto podría causar herid...

Page 29: ...elétrico Quitar las placas adaptadoras Montaje de la bomba y del acoplamiento al motor eléctrico Ver fig 5 Peligro Riesgo de electrocución La conexión eléctrica debe ser realizada por personal eléctrico cualificado 1 Colocar la pieza del acoplamiento al eje del motor eléctrico Instalar el tornillo de cierre T si procede Ver fig 6 B 2 Motor 80 Colocar la pieza del acoplamiento al eje del motor eléc...

Page 30: ...icas técnicas El peso depende del fabricante del motor Tolerancia de nivel sonoro 3 dB A Bomba Máxima presión de trabajo 10 bar Máxima temperatura del aceite 100 C Compatibilidad de fluido Aceite minerál Aceites sintéticos Aceites vegetales Aceites para turbinas Para utilizar otros aceites o para el funcionamiento bajo condiciones extremas contacte con Parker Material Bomba Aluminio acero Juntas t...

Page 31: ...irectives Safety of machinery Basic concepts general principles for design SS EN ISO 12100 1 A1 2009 and SS EN ISO 12100 2 A1 2009 Safety of machinery Safety requirements for fluid power systems and their components Hydraulics SS EN ISO 4413 2010 Pumps and pump units for liquids Common safety requirements SS EN 809 A1 2009 AC 2010 Electric motors used on the product comply with the Low Voltage Dir...

Page 32: ... motors have one or more adapter plates Komponentenverzeichnis A Pumpe B Montagesatz Wellenkupplungsteil und evtl Adapterplatte C Elektromotor D Typenschild Manche Elektromotoren haben eine oder mehrere Adapterplatten Liste des composants A Pompe B Kit de montage partie de l accouplement et éventuelle plaque d adaptation C Moteur eléctrique D Plaque signalétique Certains moteurs sont équipés d une...

Page 33: ... Group Catalogue HY10 6012 UM EU A G1 B G1 2 Y koppling Y connection Y Anschluss Connexion en Y Conexión en Y D koppling D connection D Anschluss Connexion en D Conexión en D 3 3 500041 P N Order no pos Designation QPM3 LOW PRESSURE PUMPS OlaerAB Tel 46 8 636 07 00 Fax 46 8 767 97 56 www olaer se 1 ...

Page 34: ...Installation and servicing manual Low pressure pump QPM3 34 Parker Hannifin Corporation Hydraulics Group Catalogue HY10 6012 UM EU 4 5 6 A 6 B ...

Page 35: ...Installation and servicing manual Low pressure pump QPM3 35 Parker Hannifin Corporation Hydraulics Group Catalogue HY10 6012 UM EU ...

Page 36: ...r com PT Portugal Leca da Palmeira Tel 351 22 999 7360 parker portugal parker com RO Romania Bucharest Tel 40 21 252 1382 parker romania parker com RU Russia Moscow Tel 7 495 645 2156 parker russia parker com SE Sweden Spånga Tel 46 0 8 59 79 50 00 parker sweden parker com SK Slovakia Banská Bystrica Tel 421 484 162 252 parker slovakia parker com SL Slovenia Novo Mesto Tel 386 7 337 6650 parker sl...

Reviews: