37
Installation of F37 Flange system
• Allow expansion and contraction. Do not hamper
expansion and contraction near by tube bends:
• Tube lines have to be supported in certain distances
• Use sufficient tube clamps to support weight
• Use sufficient tube clamps to protect joints from
vibration
• Vibration has to be eliminated near by the connec
-
tors
Ø [mm]
Marine/Offshore
Industrial/Landbased
L [m]
L [m]
6.0 - 12.7
1.0
1.0
12.7 - 22.0
1.1
1.2
22.0 - 32.0
1.4
1.5
32.0 - 38.0
1.5
1.5
38.0 - 57.0
1.8
2.0
57.0 - 75.0
2.0
2.0
75.0 - 76.1
2.1
76.1 - 88.9
2.2
88.9 - 102.0
2.5
102.0 - 114.0
2.5
114.0 - 168.0
2.5
168.0 - 219.0
2.5