background image

15

F37 Flange assembly instructions

Chart distance C – Parflange

®

 F37 − ISO 6164

TFV / TF – Flare flange connection

TT – Flare flange connection

Size

Flange incl.  F37 Seal + 

O-Ring (+ Sleeve)   

Order code

 

 

D1

 

 

C

 

Inch

 

Tube

2

50X3.0

F37-432-50X3.0TFVCF

42

11

2

50X5.0

F37-432-50X5.0TFVCF

38

10

2

50X6.0

F37-432-50X6.0TFVCF

35

10

2

60X3.0

F37-432-60X3.0TFVCF

46

12

2

60X5.0

F37-432-60X5.0TFVCF

46

11

2

60X6.0

F37-432-60X6.0TFVCF

46

11

2 1/2

60X3.0

F37-440-60X3.0TFVCF

50

12

2 1/2

60X5.0

F37-440-60X5.0TFVCF

46

11

2 1/2

60X6.0

F37-440-60X6.0TFVCF

46

11

2 1/2

73X7.0

F37-440-73X7.0TFVCF

56

13

2 1/2

75X3.0

F37-440-75X3.0TFVCF

60

10

2 1/2

75X5.0

F37-440-75X5.0TFVCF

60

10

3

75X3.0

F37-448-75X3.0TFVCF

66

10

3

75X5.0

F37-448-75X5.0TFVCF

62

10

3

90X3.5

F37-448-90X3.5TFVCF

72

15

3

90X5.0

F37-448-90X5.0TFVCF

72

14

3

90X9.0

F37-448-90X9.0TFVCF

69

17

D

1

C

Size

2 Flange incl.   

2 x O-Ring (2 x Sleeve)  

Order code

 

 

D1

 

 

C

 

Inch

 

Tube

2

50X3.0

F37-432-50X3.0TTCF

42

22

2

50X5.0

F37-432-50X5.0TTCF

38

20

2

50X6.0

F37-432-50X6.0TTCF

35

20

2

60X3.0

F37-432-60X3.0TTCF

46

24

2

60X5.0

F37-432-60X5.0TTCF

46

22

2

60X6.0

F37-432-60X6.0TTCF

46

22

2 1/2

60X3.0

F37-440-60X3.0TTCF

50

24

2 1/2

60X5.0

F37-440-60X5.0TTCF

46

22

2 1/2

60X6.0

F37-440-60X6.0TTCF

45

22

2 1/2

73X7.0

F37-440-73X7.0TTCF

56

26

2 1/2

75X3.0

F37-440-75X3.0TTCF

60

20

2 1/2

75X5.0

F37-440-75X5.0TTCF

60

20

3

75X3.0

F37-448-75X3.0TTCF

66

20

3

75X5.0

F37-448-75X5.0TTCF

62

20

3

90X3.5

F37-448-90X3.5TTCF

72

30

3

90X5.0

F37-448-90X5.0TTCF

72

28

3

90X9.0

F37-448-90X9.0TTCF

69

34

D

1

C

C

after

flaring

before

Summary of Contents for ParflangeF37

Page 1: ...Installation guide Parflange F37 system Flare Flanges...

Page 2: ...er assembly instructions can you be assured of the reliability and safety of the products and their conformity to the applicable standards Failure to follow this rule can adversely affect the function...

Page 3: ...Tube preparation Chart distance C Tube flaring with Parflange 170 Checking of flare Tube cleaning and transportation preparation Installation of F37 Flange system Installation of Flare Flanges Approp...

Page 4: ...des of experience The Parflange system belongs to Parker s leak free Dry Technology programme Dry Technology stands for leak free systems with soft sealing at every connection point Parflange F37 The...

Page 5: ...ether a soft sealed high pressure tube connection is made Available as tube to tube connection or tube to port connection Retaining Ring Connection The retaining ring used in this connection is a stai...

Page 6: ...e sizes as well Flange to Port the flanged tube is connected by the flange insert and F37 seal to a port Inserts with Bonded Seal can be used alternatively Tube to Block instead of using flange bends...

Page 7: ...sion dimension shape excellent smooth surface after roll flaring high pressure capability Welded tubes and pipes Tubes and pipes acc to above specification but welded and cold redrawn instead of seaml...

Page 8: ...ngth 2 7 Tube certification min 355 533 N mm2 197 N mm2 yield strength 1 8 5 1 4404 316L DIN EN 10216 5 min 210 500 N mm2 131 N mm2 0 2 proof stress 1 6 ASTM 269 A213 TP 316 L and tube certification m...

Page 9: ...pipe Shoot through at least 2 projectiles Above 60 mm High pressure hot water cleaning Preserve the contact surfaces and the tube inside with e g oil See standad ISO 4416 old nas 1638 for cleanliness...

Page 10: ...X4 0TFVCF 90 0 14 5 140X4 5 F37 180 140X4 5TFVCF 122 0 15 6 165X5 0 F37 196 165X5 0TFVCF 150 8 17 D1 C TFV TF Flare flange connection TT Flare flange connection Size Inch Tube Flange incl Insert 2 x O...

Page 11: ...33 5 10 0 1 1 2 42X4 0 F37 324 42X4 0TFVCF 31 5 10 0 1 1 2 50X3 0 F37 324 50X3 0TFVCF 36 0 11 0 1 1 2 50X5 0 F37 324 50X5 0TFVCF 36 0 10 0 1 1 2 50X6 0 F37 324 50X6 0TFVCF 35 0 10 0 D1 C Size 2 Flang...

Page 12: ...5 F37 348 90X3 5TFVCF 72 0 15 0 3 90X5 0 F37 348 90X5 0TFVCF 72 0 14 0 Size 2 Flanges incl Insert 2 x O Ring 2 x Sleeve Order code D1 C Inch Tube 2 50X3 0 F37 332 50X3 0TTCF 41 5 22 2 50X5 0 F37 332 5...

Page 13: ...5 0 10 0 1 1 2 42X4 0 F37 624 42X4 0TFVCF 33 5 10 0 1 1 2 50X3 0 F37 624 50X3 0TFVCF 31 5 11 0 1 1 2 50X5 0 F37 624 50X5 0TFVCF 36 0 10 0 1 1 2 50X6 0 F37 624 50X6 0TFVCF 36 0 10 0 D1 C Size 2 x Flang...

Page 14: ...10 0 2 50X6 0 F37 632 50X6 0TFVCF 37 5 10 0 2 60X3 0 F37 632 60X3 0TFVCF 35 0 12 0 2 60X5 0 F37 632 60X5 0TFVCF 46 0 11 0 2 60X6 0 F37 632 60X6 0TFVCF 46 0 11 0 D1 C Size 2 x Flanges incl Insert 2 x O...

Page 15: ...75X3 0TFVCF 66 10 3 75X5 0 F37 448 75X5 0TFVCF 62 10 3 90X3 5 F37 448 90X3 5TFVCF 72 15 3 90X5 0 F37 448 90X5 0TFVCF 72 14 3 90X9 0 F37 448 90X9 0TFVCF 69 17 D1 C Size 2 Flange incl Insert 2 x O Ring...

Page 16: ...ssemblies Worn tools must be replaced Use only genuine Parker Parts Tools must always be kept clean and lubricated Clean pin for checking Visual check Surface must be free of wear and damage Clean die...

Page 17: ...38 MF37 38 BF37 38 60 42 MF37 42 BF37 38 60 48 3 MF37 48 3 BF37 38 60 50 MF37 50 BF37 38 60 60 MF37 60 BF37 60 75 60 3 MF37 60 3 BF37 60 75 65 MF37 FRAME73 90 MF37 65 E BF37 60 75 73 MF37 73 MF37 73E...

Page 18: ...w all safety instructions Select suitable flanging pin according to tube dimension Check flanging pin for dirt wear and damage Safety cover must be open Main spindle in rear position Open clamping bar...

Page 19: ...ing clamping die frame Insert clamping die set with 37 side pointing towards main spindle Close clamping bar but do not tighten yet 6 Tube stop Swing in tube stop bar Adjust tube stop wheel according...

Page 20: ...y pumping until spindle stop and flanging pressure is achieved Open valve to retract the spindle 12 open close Spindle will return to rear position Press OFF button to stop spindle rotation Safety cov...

Page 21: ...0 12 5 2 0 32 9X3 5 17 0 1 5 33 4X4 6 16 0 2 0 38X2 5 5 5 100 0 5 38X3 0 5 5 150 1 0 38X4 0 3 5 1 0 38X5 0 2 5 1 0 42X3 0 7 0 1 0 42X4 0 5 0 1 0 48 3X3 7 12 5 1 5 50x3 0 14 5 1 0 50X5 0 11 0 200 2 0...

Page 22: ...le and concentric with tube Dimensional check of the flare outside diameter see next page Flaring will cause a reduction of wallthick ness in the flare section x A lip inside the flare indicates overf...

Page 23: ...5 44 0 38X3 0 44 0 38X4 0 44 0 38X5 0 44 0 42X3 0 48 0 42X4 0 48 0 48 3X3 7 56 0 50x3 0 58 0 50X5 0 58 0 50X6 0 58 0 60X3 0 68 0 60X5 0 68 0 60X6 0 68 0 60 3X3 9 68 5 65X8 0 76 0 73x7 0 82 8 75X3 0 82...

Page 24: ...ile Release the trigger when the projectile has exit the pipe Shoot through at least 2 projectiles Above 60 mm High pressure hot water cleaning or oil flushing Preserve the contact surfaces and the tu...

Page 25: ...page recomenn ded lubrication MOLYKO TE G RAPID PLUS 3 4 ISO 4762 DIN 912 Flared pipe must be clean Use plastic hammer to fix insert if neccessary Avoid damage of sealing surfaces 1 2 Flared pipe mus...

Page 26: ...ediately to avoid pollution of the thread or the surface Parker recommends to use only calibrated manuall or hydraulic torque tools 6 7 The friction coefficient is strongly affected by proper lubricat...

Page 27: ...nough space for mounting and tooling 8 Parker recommends to tighten the tube connec tion at first After that the tube clamps can be tightend 9 The tubes flanges have to be parallel and axial aligned b...

Page 28: ...ceeding the working pressure of the flange e g PN x 1 5 test pressure a repeat of step 6 is required after the pressure test 7 Retightening might be required after one week of operation depending on t...

Page 29: ...sted with a pressure exceeding the working pressure of the flange e g PN x 1 5 test pressure a repeat of step 6 is required after the pressure test 7 Retightening might be required after one week of o...

Page 30: ...ge e g PN x 1 5 test pressure a repeat of step 3 is required after the pressure test 4 Retightening might be required after one week of operation depending on the dynamic of the system We recommend to...

Page 31: ...t tightening Parker recommends to take mounting documentation for every flange connection Reassembly Mark the component positions before disconnecting Check seals for damage and deformation and replac...

Page 32: ...ZYLS10X40 4x ZYLX10X65 4x ISO4032 M10 not recommended 31Nm 31Nm 31Nm F37 124 4x ZYLS12X40 4x ZYLS12X70 4x ISO4032 M12 not recommended 45Nm 50Nm 45NM F37 132 4x ZYLS12X45 4x ZYLS12X80 4x ISO4032 M12 no...

Page 33: ...4x ZYLS10X40 4x ZYLS10X70 4x ISO4032 M10 43Nm 31Nm 31Nm 31Nm F37 324 4x ZYLS12X45 4x ZYLS12X80 4x ISO4032 M12 75Nm 55Nm 60Nm 55Nm F37 332 4x ZYLS12X55 4x ZYLS12X100 4x ISO4032 M12 75Nm 60Nm 65Nm 55Nm...

Page 34: ...ISO4032 M10 43Nm 31Nm 31Nm 31Nm F37 616 4x ZYLS12X45 4x ZYLS12X75 4x ISO4032 M12 75Nm 55Nm 60Nm 55Nm F37 620 4x ZYLS14X55 4x ZYLS14X90 4x ISO4032 M14 115Nm 80Nm 85Nm 80Nm F37 624 4x ZYLS16X60 4x ZYLS1...

Page 35: ...e Bonded Seal Nut Recommended torques Bolts Tube to Port Bolts Tube to Tube Black phosphated 10 9 ELZ 8 8 HDG 8 8 A4 80 F37 432 4x ZYLS16X65 4x ZYLS16X110 4x ISO4032 M16 175Nm 125Nm 140Nm 125Nm F37 44...

Page 36: ...ling make sure that there is no pressure left in the system Parker recommends that all sealings nuts and bolts are replaced before reassembling For reassembling follow the installation instructions ab...

Page 37: ...weight Use sufficient tube clamps to protect joints from vibration Vibration has to be eliminated near by the connec tors mm Marine Offshore Industrial Landbased L m L m 6 0 12 7 1 0 1 0 12 7 22 0 1...

Page 38: ...73 24 00 parker poland parker com PT Portugal Leca da Palmeira Tel 351 22 999 7360 parker portugal parker com RO Romania Bucharest Tel 40 21 252 1382 parker romania parker com RU Russia Moscow Tel 7 4...

Reviews: