16
F37 Flange assembly instructions
• Use of damaged, worn or non-suitable tooling may result in
flange failure and damage of machine
• Tools must be checked regularly, at least after 50 assemblies
• Worn tools must be replaced
• Use only genuine Parker Parts
• Tools must always be kept clean and lubricated
• Clean pin for checking
• Visual check:
Surface must be free of
wear and damage
• Clean die halves for
checking
• Visual check:
Grip surface must be
clean and free of wear
• Use wire-brush to
remove metal particles
from grip surface
1
2
Checking instructions for Parflange
®
tools