Communication
12
COMMUNICATION PROTOCOL IS BY RS485/MODBUS
Item
Specification
Transmission code
RTU
Start bit
1
Data length
8
Parity
Even/ Odd/ No Parity
Stop bit
1 (Either 1 or 2 is
selectable at no parity)
BAUD RATE
Address Switch
Contents
50
57.6 kbps
51
38.4 kbps
52
19.2 kbps
Other settings not defined.
-
TRANSMISSION MODE
Address switch
Contents
60
RTU
Other settings not defined
-
Item
Specification
Baud rate (Unit : K bps)
57.6, 38.4, 19.2
Transmission mode
RTU MODE
Parity
Even number, Odd
number, No parity
Stop bit
1 or 2
Mode and Byte Composition
You can monitor flow rate with the PAFC-100 through the communication protocol. You may also access and
define the parameters using the communication protocol. Refer to the following sections for details.
Required Setting Parameters
Setting Method
Communication parameters for the PAFC-100 can be set up only on the converter side, i.e. local setting.
Press and hold zero adjusting button for more than 2 seconds after changing address switch. If input is
completed, three LED lamps will blink for 5 seconds at intervals of 1Hz.