Levels of protection for the various equipment categories

The various equipment categories must be capable of operating in
accordance with the manufacturer’s operating specifications at defined
levels of protection.

Level of

Category

Type of protection

Operating specifications

protec-

Group

Group

tion

I

II

Very

M1

Two independent means of protection or safety, ensuring that

The equipment remains energised and

high

the equipment remains functional even in the event of two faults

and functional even with an explosive

occurring independently of each other

atmosphere present

Very

1

Two independent means of protection or safety, ensuring that

The equipment remains energised and

high

the equipment remains functional even in the event of two faults

functional in zones 0, 1, 2 (G) and/or

occurring independently of each other

zones 20, 21, 22 (D)

High

M2

 

Protection suitable for normal operation and severe

The equipment is de-energised in the

operating conditions

event of an explosive atmosphere

High

 

2

Protection suitable for normal operation and frequent faults, or

The equipment remains energised and func-

equipment in which faults normally have to be taken into account tional in zones 1, 2 (G) and/or zones 21, 22 (D)

Normal

 

3

Protection suitable for normal operation

The equipment remains energised and func-
tional in zones 2 (G) and/or zones 22 (D)

G = gas and D = dust

Temperature classes

Classification of flammable gases and vapours on the basis of ignition temperature

Group

I

II

mines, combustible vapours

other potentially explosive atmospheres (gases, dust)

Category

M1

M2

1

2

3

Atmosphere*

 

 

G

D

G

D

G

D

Zone

 

 

0

20

1

21

2

22

Declaration of conformity

The product catalogues contain copies of the declaration of conformity
demonstrating that the product meets the requirements of directive 94/9/
EC.
The declaration is only valid in conjunction with the instructions
contained in the installation manual relating to the safe use of the
product throughout its service life.
The instructions relating to the conditions in the surrounding area are
particularly important, as the certificate is invalidated if the instructions
are found not to have been adhered to during operation of the product.
If there is any doubt as to the validity of the certificate of conformity,
contact Parker Hannifin customer service.

Temperature class

Ignition temperature °C

T1

Over 450

T2

(300) – 450

T3

(200) – 300

T4

(135) – 200

T5

(100) – 135

T6

(85) - 100

Operation, installation and maintenance

The installation manual of the product contains instructions relating to
the safe storage, handling, operation and servicing of the product.
The manual is available in different languages, and can be downloaded
from 

www.parker.com/euro_pneumatic

.

This document must be made accessible in a suitable place near where
the product is installed. It is used as a reference for all personnel
authorised to work with the product throughout its service life.
We, the manufacturer, reserve the right to modify, extend or improve the
installation manual in the interests of the users.

For more information about ATEX see EUs homepage:  

http://europa.eu.int/comm/enterprise/atex/

Definition of groups

 (EN 1127-1)

Group I

Equipment intended for use in underground parts of mines as well as those parts of surface installations of such mines likely to be
endangered by flammable vapours and/or flammable dusts.

Group II

Equipment intended for use in other places exposed to explosive atmospheres.

Summary of Contents for P1D Series

Page 1: ...Catalogue 9127007812GB ul Pneumatic cylinders Series P1D According to ISO VDMA and AFNOR...

Page 2: ...es at any time without notice Important Before carrying out service activities make sure the cylinder is vented Before disassembling the cylinder disconnect the primary air hose to ensure that the air...

Page 3: ...uld only be achieved by using the best possible materials and methods The result is a complete family of ISO VDMA cylinders of which we are very proud P1D is a high technology cylinder design for just...

Page 4: ...such as Through piston rod high and low temperature hydraulic operation extended piston rod etc A new special variant is the unique self lubricating HDPE scraper ring and piston rod seal specially de...

Page 5: ...in type and are quickly and easily installed in the T groove from the side Both the cable and the sensor are protected in the groove Choose a sensor with 3 or 10 m cable 8 mm connector or the new M12...

Page 6: ...431 ISO 15552 VDMA 24562 and AFNOR standards The exception is the somewhat larger footprint of the end covers and envelope of the body extrusion due to the so called positive geometry hygienic convex...

Page 7: ...n two dedicated grooves beneath a transparent sealed moulding Tightening the stop screw onto the cam shaft will lock each sensor in the desired position with great force The sensor LEDs are always ful...

Page 8: ...ndards Apart from the projecting connections on sizes 32 63 mm P1D Flexible Porting complies with ISO 6431 ISO 15552 VDMA 24562 and AFNOR standards Common high technology design platform P1D Flexible...

Page 9: ...he other end has plugs in the cylinder ports These plugs can be moved to the other end to suit the application Mechanically protected drop in sensors The body extrusion which is common to all P1D Clea...

Page 10: ...n engineering plastics with excellent bearing properties and the initial greasing at the factory with a transparent foodstuffs approved grease Altogether this gives the P1D very long service life and...

Page 11: ...nd piece of the cylinder The lock unit can be used for braking as well as locking With no signal pressure the full force of the lock is applied to the piston rod and the lock is released at 4 bar sign...

Page 12: ...rease for their particular temperature ranges The high temperature version does not have magnetic piston no function at high temperatures The low temperature cylinders do have magnetic piston but reme...

Page 13: ...0 248 Mass moving parts only for cushioning calculation Cylinder Mass moving parts kg designation at 0 mm stroke Supplement per 10 mm stroke All variants All variants P1D 032 X 0 13 0 009 P1D 040 X 0...

Page 14: ...and trouble free operation ISO 8573 1 quality class 3 4 3 should be used This means 5 m filter standard filter dew point 3 C for indoor operation a lower dew point should be selected for outdoor opera...

Page 15: ...ie rods Stainless steel X 10 CrNiS 18 9 Design variants Low temperature design Seals scraper ring Polyurethane PUR Piston Anodised aluminium Piston piston rod bearing UHMWPE plastic High temperature d...

Page 16: ...cylinder If you want to use the capacity of the valve to its maximum and obtain maximum speed the tubing should be chosen so that they at least correspond with the equivalent restriction diameter see...

Page 17: ...3 7 meter Intersection three When a tube 14 will be used the maximum length of tube is 6 meter Example 4 Determining tube size and cylinder velocity with a particular cylinder and valve For an applica...

Page 18: ...ithin these zones The table below describes the zones in an installation where there is a potential for explosive atmospheres The owner of the installation must analyse and assess the area in which th...

Page 19: ...here G D G D G D Zone 0 20 1 21 2 22 Declaration of conformity The product catalogues contain copies of the declaration of conformity demonstrating that the product meets the requirements of directive...

Page 20: ...st not be used for driving the cylinder 7 Check that the P1D S cylinder is not equipped with a metal scraper ring special version Installation requirements in Ex areas The temperature of the supply ai...

Reviews: