background image

17

P1D

Cylinder

05.03

www.parker.com/euro_pneumatic

Example  1  : Which tube diameter should be used?

A 50 mm bore cylinder is to be operated at 0.5 m/s. The tube
length between the valve and cylinder is 2 m. In the diagram we
follow the line from 50 mm bore to 0.5 m/s and get an “equivalent
throttling bore“ of approximately 4 mm. We continue out to the
right in the chart and intersect the line for a 2 m tube between
the curves for 4 mm (6/4 tube) and 6 mm(8/6 tube). This means
that a 6/4 tube throttles the velocity somewhat, while an 8/6 tube
is a little too large. We select the 8/6 tube to obtain full cylinder
velocity.

Example  2 : What cylinder velocity will be obtained?

A 80 mm bore cylinder will be used, connected by 8 m 12/10
tube to a P2L-B valve. What cylinder velocity will we get? We
refer to the diagram and follow the line from 8 mm tube length up
to the curve for 12/10 tube. From there, we go horizontally to the
curve for the Ø80 cylinder. We find that the velocity will be about
0.5 m/s.

Example  3 : What is the minimum inner diameter and
maximum lenght of tube?

For a application a 125 mm bore cylinder will be used. Maximum
velocity of piston rod is 0.5 m/s. The cylinder will be controlled by
a P2L-D valve. What diameter of tube can be used and what is
maximum lenght of tube.
We refer to the diagram. We start at the left side of the diagram
cylinder Ø125. We follow the line until the intersection with the
velocity line of 0.5 m/s. From here we draw a horizontal line in the
diagram. This line shows us we need an equivalent throttling
bore of approximately 10 mm. Following this line horizontally we
crosses a few intersections. These intersections shows us the
minimum inner diameter (rightside diagram) in combination with
the maximum length of tube (bottomside diagram).

For example:
Intersection one: When a tube (14/11) will be used,
the maximum length of tube is 0.7 meter.
Intersection two: When a tube (—/13) will be used,
the maximum length of tube is 3.7 meter.
Intersection three: When a tube (—/14) will be used,
the maximum length of tube is 6 meter.

Example  4  :  Determining tube size and cylinder
velocity with a particular cylinder and valve?

For an application using a 40 mm bore cylinder with a valve with
Qn=800 Nl/min. The distance between the cylinder and valve
has been set to 5 m.

Tube dimension: 

What tube bore should be selected to obtain

the maximum cylinder velocity? Start at pipe length 5 m, follow
the line up to the intersection with 800 Nl/min. Select the next
largest tube diameter, in this case Ø10/8 mm.

Cylinder velocity:

     What maximum cylinder velocity will be

obtained? Follow the line for 800 Nl/min to the left until it
intersects with the line for the Ø40 mm cylinder. In this example,
the speed is just above 1.1 m/s.

Valve series with respective flows in Nl/minute

Valve series

Qn in Nl/Min

Valvetronic Solstar

33

Interface PS1

100

Valvetronic Interface 2000

100

B2 Series

168

Adex A05

173

Moduflex size 1, (2 x 3/2)

220

Valvetronic PVL-B 5/3 closed centre, 6 mm push in

290

Moduflex size 1, (4/2)

320

B43 Manual and mechanical

340

Valvetronic PVL-B 2 x 2/3, 6 mm push in

350

Valvetronic PVL-B 5/3 closed centre, G1/8

370

Valvetronic PVL-B 2 x 3/2 G1/8

440

Valvetronic PVL-B 5/2, 6 mm push in

450

Valvetronic PVL-B 5/3 vented centre, 6 mm push in

450

Moduflex size 2, (2 x 3/2)

450

Compact Isomax DX01

480

Flowstar P2V-A

520

Valvetronic PVL-B 5/3 vented centre, G1/8

540

Valvetronic PVL-B 5/2, G1/8

540

Valvetronic PVL-C 2 x 3/2, 8 mm push in

540

Adex A12

560

Valvetronic PVL-C 2 x 3/2 G1/8

570

Compact Isomax DX02

700

Valvetronic PVL-C 5/3 closed centre, 8 mm push in

700

Valvetronic PVL-C 5/3 vented centre, G1/4

700

VIKING P2L-A

760

B3 Series

780

Valvetronic PVL-C 5/3 closed centre, G1/4

780

Moduflex size 2, (4/2)

800

Valvetronic PVL-C 5/2, 8 mm push in

840

Valvetronic PVL-C 5/3 vented centre, 8 mm push in

840

Valvetronic PVL-C 5/2, G1/4

840

VIKING P2L-B

1020

Flowstar P2V-B

1090

ISOMAX DX1

1120

B53 Manual and mechanical

1160

B4 Series

1170

Airline Isolator Valve VE22/23

1470

ISOMAX DX2

2880

VIKING P2L-D

2880

ISOMAX DX3

4360

Airline Isolator Valve VE42/43

5520

Airline Isolator Valve VE82/83

13680

Summary of Contents for P1D Series

Page 1: ...Catalogue 9127007812GB ul Pneumatic cylinders Series P1D According to ISO VDMA and AFNOR...

Page 2: ...es at any time without notice Important Before carrying out service activities make sure the cylinder is vented Before disassembling the cylinder disconnect the primary air hose to ensure that the air...

Page 3: ...uld only be achieved by using the best possible materials and methods The result is a complete family of ISO VDMA cylinders of which we are very proud P1D is a high technology cylinder design for just...

Page 4: ...such as Through piston rod high and low temperature hydraulic operation extended piston rod etc A new special variant is the unique self lubricating HDPE scraper ring and piston rod seal specially de...

Page 5: ...in type and are quickly and easily installed in the T groove from the side Both the cable and the sensor are protected in the groove Choose a sensor with 3 or 10 m cable 8 mm connector or the new M12...

Page 6: ...431 ISO 15552 VDMA 24562 and AFNOR standards The exception is the somewhat larger footprint of the end covers and envelope of the body extrusion due to the so called positive geometry hygienic convex...

Page 7: ...n two dedicated grooves beneath a transparent sealed moulding Tightening the stop screw onto the cam shaft will lock each sensor in the desired position with great force The sensor LEDs are always ful...

Page 8: ...ndards Apart from the projecting connections on sizes 32 63 mm P1D Flexible Porting complies with ISO 6431 ISO 15552 VDMA 24562 and AFNOR standards Common high technology design platform P1D Flexible...

Page 9: ...he other end has plugs in the cylinder ports These plugs can be moved to the other end to suit the application Mechanically protected drop in sensors The body extrusion which is common to all P1D Clea...

Page 10: ...n engineering plastics with excellent bearing properties and the initial greasing at the factory with a transparent foodstuffs approved grease Altogether this gives the P1D very long service life and...

Page 11: ...nd piece of the cylinder The lock unit can be used for braking as well as locking With no signal pressure the full force of the lock is applied to the piston rod and the lock is released at 4 bar sign...

Page 12: ...rease for their particular temperature ranges The high temperature version does not have magnetic piston no function at high temperatures The low temperature cylinders do have magnetic piston but reme...

Page 13: ...0 248 Mass moving parts only for cushioning calculation Cylinder Mass moving parts kg designation at 0 mm stroke Supplement per 10 mm stroke All variants All variants P1D 032 X 0 13 0 009 P1D 040 X 0...

Page 14: ...and trouble free operation ISO 8573 1 quality class 3 4 3 should be used This means 5 m filter standard filter dew point 3 C for indoor operation a lower dew point should be selected for outdoor opera...

Page 15: ...ie rods Stainless steel X 10 CrNiS 18 9 Design variants Low temperature design Seals scraper ring Polyurethane PUR Piston Anodised aluminium Piston piston rod bearing UHMWPE plastic High temperature d...

Page 16: ...cylinder If you want to use the capacity of the valve to its maximum and obtain maximum speed the tubing should be chosen so that they at least correspond with the equivalent restriction diameter see...

Page 17: ...3 7 meter Intersection three When a tube 14 will be used the maximum length of tube is 6 meter Example 4 Determining tube size and cylinder velocity with a particular cylinder and valve For an applica...

Page 18: ...ithin these zones The table below describes the zones in an installation where there is a potential for explosive atmospheres The owner of the installation must analyse and assess the area in which th...

Page 19: ...here G D G D G D Zone 0 20 1 21 2 22 Declaration of conformity The product catalogues contain copies of the declaration of conformity demonstrating that the product meets the requirements of directive...

Page 20: ...st not be used for driving the cylinder 7 Check that the P1D S cylinder is not equipped with a metal scraper ring special version Installation requirements in Ex areas The temperature of the supply ai...

Reviews: