22
Modular Pneumatic Linear Drive System OSP -P / OSPP-BG
Fitting the End Caps
• Insert clamping pieces for the inner sealing band (16) into the endcap. Observe installation
position.
bevel must face towards the air connection.
• Insert clamping pieces for outer band (14) into the cover.
• Fit clamping screw (13) M2x4 for outer band (11) and clamping screws (15) M2x5 for inner sealing
band (17).
• Put pressure plate (38) on one end of the inner sealing band (17).
• Observe position of pressure plate and inner sealing band!
• Grease cover O-ring (18).
• Mount endcap (35):
insert the inner sealing band (17) with pressure plate (38) below the clamping piece for the inner seal-
ing band; the bevel of the inner sealing band must face towards the air connection.
• Fasten cover screws (36):
observe the required „Torque Moments for screws“ on page 24 as stated
.
• Align inner sealing band by slightly moving at the band rivet.
• Tighten clamping screw (15) for inner sealing band, located on the piston side.
• Push piston as far as approx. 50 mm from the opposite end position.
• Put pressure plate (38) onto the opposite end of the inner sealing band (17). Observe position of the
pressure plate and of the inner sealing band.
• Grease O-ring of cover (18).
• Mount endcap (37).
• Tighten endcap screws (36):
observe the required tightening torque of screws as stated on page 24.
• Screw home clamping screw (15) for inner sealing band.
Check tension of inner sealing band
The inner sealing band must be fitted:
• Without pre-tension.
• Without sagging
.
Complete cylinder
Attention
See the table „Torque Moments for screws“ on page 24.
• Insert the outer cover band (11) and insert the ends underneath the clamping pieces for the outer band
(14). Do not clamp.
• Mark outer cover band (11) on both sides at the end of the cylinder barrel with a pencil.
• Remove outer cover band again and bend down by approx. 20° at the marked spots using a flat pliers.
• Insert outer cover band and insert the ends underneath the clamping pieces (14) for the outer band.
• Push both wipers (8) into the piston groove (17) as far as possible.
• Mount carrier (39) and fix to piston (17) with screws (40). Press carrier (39) down slightly: observe
„
Torque Moments for screws
“ on page 24.
• Fasten clamping screws (13) for outer cover band (11) : „
Torque Moments for screws
“ on page 24.