60 - PVD 3664_GB_NK-November 2016.Docx
3.5.2.
Water cooled motor
Danger: The cooling system has to be operational when the motor is
running or energized.
Danger: The Inlet temperature and the water flow have to be monitored
to avoid any exceeding temperature values.
Caution: When motor is not running, the cooling system has to be
stopped 10 minutes after motor shut down.
Caution: Condensation and risk of rust may occur when the
temperature gradient between the air and the water becomes
significant. Condensation is also linked to hygrometry rate.
To avoid any issue, we recommend: T
water
> T
air
- 2°C.
The motor can be used with an ambient temperature between 27°C to
40°C with a high water temperature but with derating.
If inlet water temperature becomes higher than 25°C, derating factor
must be applied according to §3.1.2 Temperature Derating
Caution: the ambient air temperature shall not exceed 40°C in the
vicinity of the motor flange
Danger: If the water flow stops, the motor can be damaged or
destroyed causing accidents.
Summary of Contents for NK Series
Page 1: ...1 PVD 3664_GB_NK November 2016 Docx Servomotors NK Series Technical Manual PVD 3664_GB ...
Page 40: ...40 PVD 3664_GB_NK November 2016 Docx 3 3 Dimension drawings 3 3 1 NK1 ...
Page 41: ...41 PVD 3664_GB_NK November 2016 Docx 3 3 2 NK2 ...
Page 42: ...42 PVD 3664_GB_NK November 2016 Docx 3 3 3 NK3 ...
Page 43: ...43 PVD 3664_GB_NK November 2016 Docx 3 3 4 NK4 ...
Page 44: ...44 PVD 3664_GB_NK November 2016 Docx 3 3 5 NK6 ...
Page 45: ...45 PVD 3664_GB_NK November 2016 Docx 3 3 6 NK8 ...
Page 46: ...46 PVD 3664_GB_NK November 2016 Docx 3 3 1 NK3 W ...
Page 47: ...47 PVD 3664_GB_NK November 2016 Docx 3 3 2 NK4 W ...
Page 48: ...48 PVD 3664_GB_NK November 2016 Docx 3 3 3 NK6 W ...
Page 49: ...49 PVD 3664_GB_NK November 2016 Docx 3 3 4 NK8 W ...
Page 76: ...76 PVD 3664_GB_NK November 2016 Docx Resolver part number 220005P1003 ...