![Parker MX80S Series Product Manual Download Page 29](http://html.mh-extra.com/html/parker/mx80s-series/mx80s-series_product-manual_756309029.webp)
MX80S Series Product Manual
29
Parker Hannifin Corporation
EMN Automation
-
Parker
Irwin, Pennsylvania
Chapter 5
-
Connecting to the ViX Amplifier—
Stepper
The MX80S is designed to be plug and run compatible with the Parker ViX drive. The cables on the
MX80S are labeled to match the labels on the ViX for ease of use and quick installation. When pur-
chased as part of the part number, the ViX will have the motor parameters already downloaded.
STEPPER MOTOR LEADS
WIRE COLOR
DRIVE
RED
A+
BLACK
A
-
WHITE
B+
BLUE/RED
B
-
GREEN/YELLOW
GROUND
X5 –
LIMITS CONNECTOR*
PIN
FUNCTION
WIRE COL-
OR
1
GND
BLACK
6
Limit 2
ORANGE
7
Limit 1
BLUE
8
Home
GREEN
* For Drive Only versions of the ViX, the limits
need to be connected to the motion controller
Limits use Inputs
The ViX drive has 5 digital inputs. When using with MX80S, the EOT Limits and Home use 3 of
the 5 inputs. A VM15
-
PF screw terminal breakout board may be purchased to allow access to
the remaining 2 inputs and all of the outputs.