The Pro Display ISOBUS Suite supports ISOBUS power management commands. ISOBUS
compatible tractor ECU provides ignition key state on ISOBUS and if the ignition key is switched
off, the ISOBUS power is shutdown in 2 seconds unless an some ISOBUS device requests for the
power to remain ON for another 2 seconds. Pro Display will send this request to maintain
power until it is shut down manually from the in-cab harness ignition key switch. Note that sleep
mode is not supported with ISOBUS compatible tractors.
For other machines (for example combine harvester) Pro Display should be connected normally
as defined in Pro Display instruction book (
Document ref.: Pro Display 10” MSG17-4020IB/UK,
Pro Display 12” MSG17-4022IB/UK
).
When ISOBUS Task Controller (TC) is shutting down, the following user settings are saved to
persistent memory:
-
Section control state
-
Camera channel and automatic reverse camera mode
-
Split screen mode
-
Map layer (guidance lines and field boundaries)
-
Selected task
-
Guidance A/B points, working width and guidance enabled.