Catalogue HY29-0037-M1/UK
Overall Hydraulic Motors, Fixed
M5AS - M5ASF Denison Vane Motors
26
Parker Hannifin SAS
VPDE, Denison Vane Motors
Vierzon - France
6 . Put back the 4 screws.
7 . Tighten to the correct torque
(see table hereunder).
end cap with porting changed
3 . 3 . cHAnging PorTing orienTATion :
conversions
a) Always check if the shaft rotates. (a slight resistance due to the spring loaded vanes is
normal). Otherwise, please go back to the previous step.
b) Check the porting configuration (see table page 30).
c) Tighten the 4 screws step by step to avoid damaging the seals.
d) Always check if the shaft rotates.
If not, disassemble and go back to the previous step.
!
1
4
3
2
TigHTening Torque :
100 Nm
73.8 Ft.lbs