MA-K17510-KW LinerSCAN manual ISSUE P.doc
Page 77 of 93
5. Remove the oil inlet hose from the sensor as shown, and place a container capable of holding
at least 750ml of oil over the hose end. Allow any oil to flow into the container, and then empty
the container for the test.
6. Slowly pour 500ml of new cylinder oil over the edge of the cylinder as shown. The objective is
to mimic oil flowing from the liner into the scavenge space
7. After allowing up to 60 minutes for the oil to flow, verify that the container has received
≥
300ml
of oil
8. Once completed:
9. Turn all isolation valves are OFF
Summary of Contents for Kittiwake LinerSCAN
Page 9: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 8 of 93 3 Installation Installation...
Page 34: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 33 of 93 4 Commissioning Commissioning...
Page 40: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 39 of 93 5 Operation Operation Manual...